ICP NUGK100DH03 gas furnace

ICP NUGK100DH03 gas furnace Parts

Here are the diagrams and repair parts for ICP NUGK100DH03 gas furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for NUGK100DH03 Gas Furnace

  • 5 Mfd 440/37 for ICP NUGK100DH03 - Part TRCF5

    Functional replacement parts diagram

    Capacitor

    Part #602974

    Replaced by #TRCF5

    Info Icon
    Manufacturer substitution
    This part replaces 602974. Substitute parts can look different from the original.
    In Stock
    $29.15
    Minus Item
    Qty
    Plus Item
  • Module for ICP NUGK100DH03 - Part 612919

    Module

    Part #612919

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Blower Fan Motor for ICP NUGK100DH03 - Part 613209

    Functional replacement parts diagram

    Furnace Blower Fan Motor

    In Stock
    $770.59
    $12.00 OFF Phone Price : $782.59Info Icon
    Minus Item
    Qty
    Plus Item
  • Tube for ICP NUGK100DH03 - Part 1000633

    Non-functional replacement parts diagram

    Tube

    In Stock
    $31.97
    Minus Item
    Qty
    Plus Item
  • Clamp Cap for ICP NUGK100DH03 - Part 706439

    Non-functional replacement parts diagram

    Clamp Cap

    In Stock
    $657.96
    Minus Item
    Qty
    Plus Item
  • Clamp for ICP NUGK100DH03 - Part 1001328

    Non-functional replacement parts diagram

    Clamp

    In Stock
    $31.97
    Minus Item
    Qty
    Plus Item
  • Manifold for ICP NUGK100DH03 - Part 1000345

    Non-functional replacement parts diagram

    Manifold

    In Stock
    $216.09
    Minus Item
    Qty
    Plus Item
  • Clamp for ICP NUGK100DH03 - Part 94364

    Non-functional replacement parts diagram

    Clamp

    In Stock
    $758.31
    Minus Item
    Qty
    Plus Item
  • Panel for ICP NUGK100DH03 - Part 95143

    Non-functional replacement parts diagram

    Panel

    In Stock
    $58.39
    Minus Item
    Qty
    Plus Item
  • Panel for ICP NUGK100DH03 - Part 1004361

    Non-functional replacement parts diagram

    Panel

    In Stock
    $208.97
    Minus Item
    Qty
    Plus Item

ICP Gas Furnace NUGK100DH03 FAQs

Restricted airflow from a dirty air filter is the most common cause of a gas furnace shutdown, but the most commonly replaced parts are usually ignition and airflow components. On an Icp gas furnace model NUGK100DH03, frequent failures involve the blower system (motor, wheel, capacitor) or a safety switch that stops heat when conditions are unsafe.

Most common furnace failures (what we see most often)

  • Clogged air filter causing overheating and a safety shutdown
  • Blower problems: weak airflow, squealing, or no air movement
  • Ignition/sensing issues: furnace tries to light, then shuts off
  • Safety switch trips (door switch, pressure-type switch, rollout-type safety)
  • Electrical issues: loose wiring, blown fuse, tripped breaker

Parts on NUGK100DH03 that commonly get replaced

If your furnace runs but airflow is weak or the blower will not start, these are the first parts we check on this model’s parts list:

Quick symptom-to-part guide

Symptom Most likely area Common next step
Furnace heats briefly, then shuts off Airflow restriction or safety limit Replace filter; check vents and blower airflow
Blower hums but will not spin Capacitor or motor Test capacitor; inspect motor
Loud rattling or vibration Blower wheel Inspect wheel for damage or looseness
No blower at all (but furnace has power) Control/safety circuit Check door switch, wiring, and control relay

Why it matters

A furnace is designed to shut down when it cannot move enough air or when a safety circuit detects a problem. Fixing the root cause (often airflow) prevents repeat shutdowns and protects major components like the heat exchanger.

Last updated: February 2026

For an Icp gas furnace like model NUGK100DH03, the most expensive repair is typically a heat exchanger replacement because it is labor-intensive and tied to safe combustion. Among common serviceable parts, a blower motor or inducer (draft) motor assembly is often the priciest.

Most expensive furnace repairs (typical)

These are the repairs that usually drive the highest total cost (part plus labor):

  • Heat exchanger: often the highest-cost repair due to disassembly and safety checks
  • Inducer (draft) motor assembly: high part cost; affects venting and ignition
  • Blower motor: high part cost; affects airflow and comfort
  • Control board (if equipped): can be expensive and requires careful diagnosis
  • Gas valve: moderate-to-high cost; must be set up and tested correctly

What that means for NUGK100DH03 parts on this page

On this model’s parts list, the highest-priced items are major motors. If you are comparing “most expensive part” strictly by part price, these are the usual top contenders:

Component type Example part on this model page Why it gets expensive
Inducer/vent motor assembly Furnace blower 1011350 Critical for safe venting; larger assembly cost
Circulating blower motor Furnace blower fan motor 613209 High-horsepower motor; higher replacement cost

Quick checks before replacing an expensive part

We recommend confirming the failure first; many “bad motor” symptoms are caused by simpler issues.

  • Turn off power to the furnace before inspecting wiring or components
  • Check the air filter and supply/return vents for restrictions (overheating can mimic motor problems)
  • Inspect wiring connections for looseness, heat damage, or corrosion
  • If the blower will not start, test the run capacitor (a common, lower-cost failure)
  • If the inducer will not run, verify the pressure switch and venting are not blocked

Helpful DIY skill for diagnosis: how to use a multimeter to test electrical parts video

Why it matters

The “most expensive part” is not always the right part to replace first. Accurate diagnosis prevents repeat breakdowns, protects comfort and safety, and avoids spending on a motor or assembly when the real issue is a capacitor, switch, or wiring problem.

Last updated: February 2026

The most common repairs on an Icp gas furnace like model NUGK100DH03 involve airflow problems (dirty filter or blower issues), ignition or flame-sensing problems, and electrical control failures. Many “no heat” calls trace back to a few serviceable parts and basic checks.

Most common repairs we see (and what they look like)

  • Dirty air filter or blocked return vents: weak airflow, overheating shutdowns, short cycling.
  • Flame sensor cleaning or replacement: furnace ignites then shuts off within seconds.
  • Ignition problems (hot surface igniter or pilot system, depending on design): no flame, repeated tries.
  • Blower motor or capacitor failure: no air movement, humming, intermittent starts.
  • Inducer/vent motor issues: pressure switch errors, won’t start, loud draft motor.
  • Control or relay problems: blower runs at the wrong time, won’t energize heat call.

Quick checks before replacing parts

  1. Set thermostat to Heat and raise the setpoint 3 to 5 degrees.
  2. Replace the furnace filter and open all supply registers.
  3. Check the furnace door switch is fully engaged and the access panel is seated.
  4. Verify the circuit breaker is on; if it trips again, stop and investigate wiring.
  5. If the blower will not start, test the run capacitor with a meter.

For safe electrical testing basics, use our guide how to use a multimeter to test electrical parts video.

Common parts involved on NUGK100DH03

Symptom Likely area Example part on this model
Blower hums, won’t start Run capacitor Capacitor 12907 or capacitor 12910
No airflow or noisy blower Blower motor/wheel Furnace blower fan motor 613209, furnace blower fan wheel 600587
Draft/venting problems Inducer assembly Furnace blower 1011350
Blower timing issues Fan relay/control Furnace fan control relay 1000742

Why it matters

Catching airflow, ignition, and control issues early prevents nuisance shutdowns, reduces strain on the blower and heat system, and helps avoid repeated limit trips that can shorten component life.

Last updated: February 2026

An Icp gas furnace like model NUGK100DH03 is built around a heat-making section (burners and heat exchanger) and an air-moving section (blower and controls). Common service parts include motors, capacitors, switches, relays, and burner components.

Main furnace components and what they do

  • Burner assembly: mixes gas and air and lights to create heat
  • Heat exchanger: transfers heat to the air without mixing combustion gases into your airflow
  • Inducer (draft) motor: pulls combustion air in and pushes exhaust out through the vent
  • Blower (circulating) motor and wheel: moves heated air through ductwork
  • Ignition system: ignitor and flame-sensing components that prove safe ignition
  • Controls and safeties: relays, switches, and sensors that manage operation and shut the furnace down if unsafe

Parts you may see listed for NUGK100DH03

These are examples of real replacement parts commonly tied to airflow and control issues:

Part type What it affects Example part on this model
Run capacitor Helps a motor start and run smoothly Capacitor 12907
Blower motor Airflow through vents Furnace blower fan motor 613209
Fan control relay Turns blower on and off at the right time Furnace fan control relay 1000742
Blower wheel Air movement and noise/vibration Furnace blower fan wheel 600587
Switch Safety or operational control input Switch 611872

Why it matters

Knowing the major furnace parts helps you troubleshoot symptoms faster. For example, weak airflow often points to the blower motor, blower wheel, or a failing capacitor, while no-heat problems can involve burner and safety controls.

Quick safety note before checking parts

  • Turn off electrical power at the furnace switch or breaker
  • Shut off the gas supply valve if you are opening the burner compartment
  • Let the furnace cool before touching internal components
  • Take a photo of wiring connections before removing any electrical part

Last updated: February 2026

Symptoms for gas ranges

Main causes: gas supply problem, faulty pressure regulator, clogs in burner or orifice, control system failure, faulty t…

Main causes: burner igniter switch failure, bad spark module, dirty or damaged spark electrode, wiring failure…

Repair guides for gas ranges

How to replace an oven temperature sensor on a gas range

How to replace an oven temperature sensor on a gas range

See how to replace an oven temperature sensor on a gas range.…

Repair time and Difficulty

 15 minutes or less
How to replace a range spark igniter electrode

How to replace a range spark igniter electrode

Learn how to replace the spark igniter electrode for the surface burners on a gas range or dual-fuel range.…

Repair time and Difficulty

 45 minutes or less
How to replace a gas range oven control board

How to replace a gas range oven control board

These step-by-step instructions explain how to replace an oven control board on a gas range…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Parts