Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Sharp AF-08ERL air conditioner

Sharp AF-08ERL air conditioner Parts

Here are the diagrams and repair parts for Sharp AF-08ERL air conditioner, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for AF-08ERL Air Conditioner

  • Casing for Sharp AF-08ERL - Part PKESPA034JBF0

    Cabinet parts diagram

    Casing

    Part #PKESPA034JBF0

    The manufacturer no longer makes this part, and there's no substitute part

  • Insulator for Sharp AF-08ERL - Part PSEL-B825JEB0

    Cabinet parts diagram

    Insulator

    Part #PSEL-B825JEB0

    The manufacturer no longer makes this part, and there's no substitute part

  • Sharp Spring for Sharp AF-08ERL - Part LSPR-A006JBE0

    Cycle parts diagram

    Sharp Spring

    Part #LSPR-A006JBE0

    The manufacturer no longer makes this part, and there's no substitute part

  • Tapping Screw for Sharp AF-08ERL - Part XTPSD40P08000

    Control box parts diagram

    Tapping Screw

    Part #XTPSD40P08000

    The manufacturer no longer makes this part, and there's no substitute part

Sharp Air Conditioner AF-08ERL FAQs

Sharp is a Japanese brand; Sharp Corporation is headquartered in Japan. For your Sharp AF-08ERL room air conditioner, the brand origin is Japan even though some units and components may be manufactured in different countries.

Quick details for Sharp air conditioners

  • Brand: Sharp
  • Brand origin: Japan
  • Typical labeling: “Sharp” on the front badge and on the rating label
  • Model example on this page: AF-08ERL
  • Where to confirm your exact unit’s manufacturing country: the rating label on the cabinet

How to check the country of manufacture on your AF-08ERL

The brand’s home country and the unit’s manufacturing country are not always the same. To see where your specific air conditioner was made, check the rating label (usually on the side of the cabinet, behind the front grille, or near the power cord area).

  1. Unplug the room air conditioner.
  2. Locate the rating label.
  3. Look for fields such as “Made in”, “Manufactured in”, or “Country of origin”.

What you’ll typically see on the label

Label item What it tells you Why it matters
Brand “Sharp” Confirms the brand family for parts and specs
Model number “AF-08ERL” Ensures you match the correct parts list
Electrical rating Volts/amps/watts Helps prevent breaker trips and overheating
Country of manufacture “Made in …” Identifies where that specific unit was assembled

Why it matters

When you’re troubleshooting cooling problems, ordering replacement parts, or checking electrical requirements, the model number (AF-08ERL) is the key identifier. The manufacturing country is useful background information, but it is not what determines parts compatibility.

Last updated: February 2026

A 0.9 ton room air conditioner is typically sized for a small room, about 90 to 150 sq ft (roughly 8 to 14 sq m) with average ceiling height and normal sun exposure. For your Sharp AF-08ERL, the best match depends on insulation, windows, and heat load.

Quick sizing guide (what 0.9 ton usually covers)

Use these common rules of thumb for a room air conditioner:

  • 90 to 120 sq ft: good fit for most bedrooms and small offices
  • 120 to 150 sq ft: works if the room is well insulated and not very sunny
  • Below 90 sq ft: may cool fast but can short-cycle and feel clammy
  • Above 150 sq ft: often struggles on hot days; consider higher capacity

What changes the “right” room size

Even with the same tonnage, real-world performance changes a lot. Plan on the lower end of the range if you have:

  • Strong afternoon sun or large west-facing windows
  • Poor insulation or lots of air leaks
  • High ceilings (over about 8 ft)
  • Heat-producing equipment (PCs, TVs) or frequent cooking nearby
  • More than 2 people in the room most of the time

Simple adjustment table

Room condition Practical target for 0.9 ton
Shaded, well insulated 120 to 150 sq ft
Average home conditions 90 to 120 sq ft
Very sunny or poorly insulated 70 to 100 sq ft

Why it matters

Correct sizing helps your Sharp AF-08ERL remove humidity while maintaining steady temperature. Oversizing can lead to short run times and poor dehumidification; undersizing can run constantly and still not keep up.

For help confirming your exact model number before shopping parts or service items, use our guide: how to find your appliance model number (and what it means for parts).

Last updated: February 2026

To reset your Sharp AF-08ERL room air conditioner, fully power-cycle it: turn it off, disconnect power long enough for the control board to clear, then restore power and restart. This clears many temporary faults and restores normal operation.

Quick reset steps (power-cycle)

  • Press Power to turn the air conditioner off.
  • Unplug the unit from the wall outlet.
  • Wait 3 to 5 minutes (this lets the electronic control reset).
  • Plug the unit back in.
  • Turn it on and reselect your settings (mode, temperature, fan speed).

If you are resetting after an error or “filter” light

A reset helps, but the underlying condition still needs attention.

  • Clean the air filter and reinstall it fully (a clogged filter can trigger protection behavior).
  • Make sure the front grille is seated correctly so airflow is not blocked.
  • Confirm the unit is not in delay/protection mode (many room ACs pause briefly before restarting the compressor).
  • Verify the outlet has steady power (avoid loose plugs or overloaded power strips).
  • If the unit uses a test/reset plug (LCDI/GFCI), press TEST then RESET on the plug head.

What a reset can and cannot fix

Situation Reset helps? What to do next
Unit is unresponsive after a power flicker Yes Power-cycle and restart
Error returns immediately after reset Sometimes Check airflow, filter, and power
Compressor will not start right away Yes Wait 3 to 10 minutes for protection delay
Breaker trips or plug trips repeatedly No Stop using and troubleshoot wiring/power

Why it matters

Resetting clears “stuck” logic in the electronic control and can recover normal cooling after a surge, outage, or control glitch. If the same symptom returns, it usually points to airflow restriction, power issues, or an electrical component problem.

For safe electrical checks (like verifying power at the outlet or testing a fuse), use our guide: how to use a multimeter to test electrical parts video.

Last updated: February 2026

If your Sharp AF-08ERL room air conditioner runs but is not cooling, the most common cause is restricted airflow from a dirty filter or blocked coils. Start with cleaning, correct settings, and basic airflow checks before moving to electrical or sealed-system troubleshooting.

Quick checks that fix most “not cooling” complaints

  • Set mode to Cool and lower the set temperature at least 5°F below room temperature.
  • Set fan speed to High for testing.
  • Clean the air filter (a clogged filter can cut cooling dramatically).
  • Make sure the front intake and rear exhaust are not blocked by curtains, furniture, or a tight window opening.
  • Close doors and windows; reduce heat sources in the room.

Clean the filter and coils (airflow is everything)

A dirty filter is the top reason a room AC stops cooling well. Washable filters can usually be rinsed with mild soap and water, then fully dried before reinstalling.

Also check the coils:

  • Evaporator coil (front): dust buildup reduces heat transfer.
  • Condenser coil (rear): lint and debris prevent heat from leaving the unit.

What you should see

Symptom Likely cause What to do
Weak airflow Dirty filter or blower wheel Clean filter; inspect for heavy dust buildup
Runs constantly, little cooling Dirty coils or warm air recirculating Clean coils; improve rear ventilation
Coil icing (frost/ice) Low airflow or low refrigerant Turn off to thaw; fix airflow first

If it still won’t cool after cleaning

  • Icing returns quickly after thawing and cleaning: airflow issue is still present, or the unit may have a refrigerant problem.
  • Compressor never starts (fan runs only): possible capacitor, control, or power issue.
  • Trips breaker or shuts off: electrical fault or overheating.

For safe electrical checks, we use a meter and follow basic test steps like in how to use a multimeter to test electrical parts video.

Why it matters

Low airflow and dirty heat-exchange surfaces force the compressor to run hotter and longer, which reduces comfort and can shorten the life of the air conditioner.

Last updated: February 2026

For the Sharp AF-08ERL room air conditioner, AF-08ERL is the model number used to identify the exact unit for parts lookup and service information. It is not slang in this context; it is Sharp’s product identifier for this specific room air conditioner.

What each part of the model number typically indicates

Manufacturers use model numbers to encode basic product details. For room air conditioners like Sharp AF-08ERL, the characters often relate to series, capacity class, and feature set.

Common patterns you may see:

  • Prefix letters (AF): product line or series identifier
  • Numbers (08): often tied to capacity class (commonly around 8,000 BTU on many brands)
  • Suffix letters (ERL): revision, feature package, or production run code

Why the exact model number matters for parts

Even small model-number differences can change the fit or wiring of parts on a room air conditioner.

Using AF-08ERL helps us match:

  • Control board and user interface components
  • Fan motor and blower wheel styles
  • Thermistor/temperature sensor types
  • Power cord and internal wiring harness connections
  • Front grille, filter frame, and cabinet pieces

Quick checklist to confirm you have the right model number

Use this to make sure you are searching the correct Sharp model:

  • Check the rating label (often behind the front grille, on the side panel, or near the power cord)
  • Match the model number character-for-character (including dashes)
  • Note any serial number nearby (helpful for production variations)
  • If the label is worn, look for a stamped tag on the chassis

Model number vs. serial number (what’s different?)

Item What it identifies What we use it for
Model number (AF-08ERL) The exact product design Correct part fit and diagrams
Serial number The specific unit made Production run details

Why it matters

Room air conditioners often have multiple versions that look identical. Using the correct Sharp AF-08ERL model number prevents ordering a part that does not mount correctly, plug in correctly, or match the control settings.

For more help confirming the label location and what the numbers mean, use how to find your appliance model number (and what it means for parts).

Last updated: February 2026

Most common symptoms to help you fix your room air conditioners

Main causes: clogged condensate drain, air conditioner not leveled properly, leaky window air seals …

Main causes: bad compressor, lack of refrigerant, bad compressor start relay, electronic control board failure…

Main causes: lack of electrical power, bad electronic control board, wiring failure, bad temperature sensor…

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Main causes: turning the air conditioner off and the back on too quickly, dirty or restricted condenser coil, compressor…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: dirty air filter, air conditioner is too small for the room, temperature set too cold, control failure…

Main causes: clogged drain hole, air conditioner not leveled properly…

Effective articles & videos to help repair your room air conditioners

Tapping into a new feature in the Search Bar on Sears PartsDirect

Tapping into a new feature in the Search Bar on Sears PartsDirect

Learn about a new feature added to the Search Bar on Sears PartsDirect…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Parts