Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
American Water Heaters BFG2J5040T3NOV water heater

American Water Heaters BFG2J5040T3NOV water heater Parts

Here are the diagrams and repair parts for American Water Heaters BFG2J5040T3NOV water heater, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for BFG2J5040T3NOV Water Heaters

  • Lp Burner for American Water Heaters BFG2J5040T3NOV - Part N/A

    Lp Burner

    Part #N/A

    The manufacturer no longer makes this part, and there's no substitute part

  • Natural Burner for American Water Heaters BFG2J5040T3NOV - Part 3110024

    Water heater diagram

    Natural Burner

    Part #3110024

    The manufacturer no longer makes this part, and there's no substitute part

  • Water Heater Gas Control Valve for American Water Heaters BFG2J5040T3NOV - Part 6910795

    Water heater diagram

    Water Heater Gas Control Valve

    Part #6910795

    The manufacturer no longer makes this part, and there's no substitute part

American Water Heaters Water Heater BFG2J5040T3NOV FAQs

For the American BFG2J5040T3NOV gas water heater, it’s usually cheaper to repair when the problem is limited to a serviceable component (like ignition or safety parts) and the tank is sound; replacement makes more sense when the tank is leaking, badly corroded, or the unit has been flood-submerged (the manual calls for replacing the entire heater in that case). See the BFG2J5040T3NOV owner's manual for safety and replacement guidance.

Quick decision guide (repair vs replace)

  • Repair when you have no tank leak and the issue is isolated (pilot will not stay lit, weak ignition, minor seep at a valve).
  • Replace when the tank itself leaks, there is heavy rusting at the tank seams, or performance is failing repeatedly.
  • Replace immediately if any gas controls, burner, or pilot were submerged in water (flooding).
  • Repair when the fix is a known wear item and the rest of the heater is in good condition.
  • Replace when repair cost is approaching a large share of a new heater, especially if multiple parts are failing.

Common repairable problems on this model

These parts are commonly involved when a gas water heater will not heat or the pilot will not stay lit:

Typical symptoms and what they point to

Symptom Often repairable? Common next step
Pilot will not stay lit Yes Inspect/replace thermocouple and pilot/igniter parts
Water around the drain area Often Replace drain valve and verify tight, sealed threads
Water dripping from relief line Often Test/replace T&P valve; check for thermal expansion
Water under the tank (from tank body) No Replace the water heater

Why it matters

Repairing a safe, contained issue can restore hot water quickly and cost less than replacement. Replacing a leaking tank or a flood-submerged gas water heater avoids unsafe operation and prevents repeated breakdowns and water damage.

Last updated: February 2026

A typical 50-gallon gas water heater usually runs about $600 to $1,200 for the tank, and about $900 to $3,100 installed once you include labor and common installation materials. For your American BFG2J5040T3NOV, the final price mainly depends on venting type, gas piping changes, and local code requirements.

What drives the installed price?

Several job details can move the total up or down:

  • Venting: standard atmospheric venting is usually simpler than power-venting.
  • Gas line work: resizing or extending gas pipe adds labor and fittings.
  • Water piping updates: shutoff valves, dielectric unions, and rework for alignment.
  • Expansion control: closed systems often need an expansion tank.
  • Permits and haul-away: varies by area and contractor.

Typical cost ranges (what most homeowners see)

Item Typical range Notes
Water heater unit (50-gal gas) $600 to $1,200 Higher for premium features and venting upgrades
Basic installation labor + common materials $300 to $1,900 Wide range based on complexity
Total installed cost $900 to $3,100 Most quotes land somewhere in this band

Your BFG2J5040T3NOV installation requirements matter because they affect labor time and materials:

  • Combustion air and ventilation: the space must provide adequate air volume.
  • Gas supply sizing: pipe diameter and run length must support the heater’s BTU input.
  • Thermal expansion: in a closed water system, periodic discharge at the relief valve can indicate expansion pressure; adding an expansion tank is a common fix.

We recommend checking the venting, combustion air, and gas supply sections in the owner's manual before you compare quotes.

Why it matters

A low quote can turn expensive if the installer later discovers venting changes, gas pipe resizing, or expansion control is needed. Pricing the job correctly up front helps avoid delays, relighting issues, and nuisance relief-valve discharge.

Last updated: February 2026

A tank-style gas water heater typically lasts 8 to 12 years. For your American BFG2J5040T3NOV, regular maintenance (especially anode rod inspections and periodic draining) helps you reach the upper end of that range and reduce the risk of sudden leaks.

Typical lifespan and what affects it

Most lifespan differences come down to water conditions and maintenance.

  • Water quality: hard water and sediment speed up wear
  • Water softeners: softened water can be more corrosive and shorten tank life
  • Maintenance: flushing sediment and inspecting the anode rod slows corrosion
  • Usage: high daily demand increases burner run time and stress
  • Installation factors: venting and combustion air issues can cause poor operation

Maintenance that most improves tank life

Your manual calls out anode rod inspection as a key corrosion-control step.

  • Inspect the anode rod about every 3 years
  • Replace the anode rod when it is more than 50% depleted
  • Drain a few gallons before anode service to reduce mess and pressure
  • Keep the burner area clean and the combustion air path unobstructed
  • Follow lighting and operating instructions in the owner's manual

Common service intervals (quick guide)

Item Typical interval Why it matters
Anode rod inspection Every 3 years Protects the tank from internal corrosion
Tank draining and flushing 6 to 12 months Reduces sediment, noise, and overheating
T&P valve check Yearly Helps prevent dangerous overpressure

Signs replacement is getting close

These symptoms often show up as a tank nears end of life.

  • Rusty or discolored hot water
  • Popping or rumbling from sediment buildup
  • Moisture or leaking around the base of the tank
  • Inconsistent hot water even after basic maintenance
  • Frequent pilot or burner issues (after confirming venting and gas supply are correct)

Why it matters

Once a tank begins leaking, replacement is usually the practical fix. Staying ahead with corrosion protection (anode rod) and sediment control helps you avoid water damage and keeps recovery performance steadier.

Last updated: February 2026

On the American BFG2J5040T3NOV gas water heater, the most common problem we see is ignition trouble, especially a pilot light that will not stay lit. This is often tied to the flame-sensing safety circuit (thermocouple/pilot components) and can lead to no hot water or intermittent heating.

What usually causes it

A gas water heater needs a stable pilot flame and proper combustion air to keep the gas valve open. When the pilot drops out, the heater shuts down for safety.

Common causes include:

  • Weak or dirty pilot flame (pilot/igniter assembly issues)
  • Failing thermocouple signal (pilot safety sensing)
  • Airflow or venting problems (draft and combustion air)
  • Flammable vapor safety shutdown (some events permanently disable the heater)
  • Gas supply interruptions (especially after running out of LP gas)

Quick checks we recommend (safe, homeowner-level)

Before any hands-on work, follow the lighting and safety steps in the BFG2J5040T3NOV owner's manual.

  • Confirm the gas shutoff valve is fully open
  • If you have LP gas, smell near floor level before lighting; follow the printed gas-smell warnings
  • Watch the pilot through the viewport while lighting; repeat the igniter steps exactly as shown
  • Make sure the area around the heater is clear; never store flammables nearby
  • If the unit has been unused for 2+ weeks, run hot water at a sink for several minutes before using electrical appliances (hydrogen gas precaution)

Parts that commonly fix “pilot won’t stay lit”

If basic checks do not restore reliable ignition, these model-specific parts are common repair paths:

Symptom Likely part to check What it does
Pilot lights, then goes out Nat gas th 100108267 Senses pilot flame and keeps gas valve energized
No spark or unreliable lighting Water heater pilot igniter 100110936 Provides ignition at the pilot
Door seal leaks air, flame is unstable Water heater manifold door gasket 100112699 Seals the burner/manifold door for proper combustion

Why it matters

A pilot that will not stay lit is more than an inconvenience; it is the heater’s safety system preventing unburned gas and unsafe combustion. Stable ignition also helps prevent temperature swings and nuisance shutdowns.

Last updated: February 2026

Most common symptoms to help you fix your water heaters

Choose a symptom to see related water heater repairs.

Main causes: faulty pressure relief valve, water is overheating…

Main causes: thermostats need adjustment, water heater capacity too low, bad heating element, thermostat failure, excess…

Main causes: broken heating element, thermostat failure, excessive tank sediment, tank size too small, burner valve asse…

Main causes: thermostat temperature set too high, thermostats need adjustment, faulty thermostat, shorted heating elemen…

Main causes: loose water pipe fittings, leaky drain valve, bad temperature-pressure relief valve, leaky heating element,…

Main causes: lack of power, no gas supply, thermostat limit switch tripped, bad element, bad thermostat, gas valve failu…

Main causes: water supply needs chlorine treatment, anode rod too reactive…

Effective articles & videos to help repair your water heaters

Use the advice and tips in these articles and videos to get the most out of your water heater.

Quiz: Are you abusing your appliances?

Quiz: Are you abusing your appliances?

Take our quiz to see how well you treat your appliances. Then, find out what you can do to help them last longer.…

Water heater common questions

Water heater common questions

These common questions and answers can help you make the most of your water heater.…

Easy DIY water heater repairs

Easy DIY water heater repairs

Read about some water heater repairs that you can easily do yourself.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Garage Door Opener
Garbage Disposal
Parts
Range
Side-By-Side Refrigerator
Table Saw
Television
Upright Vacuum
Washer
Water Heater