Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

Amana 9,000BTUMODELS ptac package terminal air conditioner Parts

Here are the diagrams and repair parts for Amana 9,000BTUMODELS ptac package terminal air conditioner, as well as links to manuals and error code tables, if available.

Amana 9,000BTUMODELS ptac package terminal air conditioner
By Schematic
By Part
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for 9,000BTUMODELS Ptac Package Terminal Air Conditioner

  • Discharge Tube for Amana 9,000BTUMODELS - Part 10021201

    Alternate compressor view h617e13@alternate compressor view diagram

    Discharge Tube

    Part #10021201

    The manufacturer no longer makes this part, and there's no substitute part

  • Wire Assembly, (used On "h" Series Models) for Amana 9,000BTUMODELS - Part 10015901

    Bottom control panel diagram

    Wire Assembly, (used On "h" Series Models)

    Part #10015901

    The manufacturer no longer makes this part, and there's no substitute part

  • Use D6711804 for Amana 9,000BTUMODELS - Part D6905404

    Blower assembly diagram

    Use D6711804

    Part #D6905404

    The manufacturer no longer makes this part, and there's no substitute part

  • Used In R015 for Amana 9,000BTUMODELS - Part 10292801

    Blower assembly diagram

    Used In R015

    Part #10292801

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw for Amana 9,000BTUMODELS - Part M0233716

    Base pan weldment diagram

    Screw

    Part #M0233716

    The manufacturer no longer makes this part, and there's no substitute part

  • Shield Filte for Amana 9,000BTUMODELS - Part D9821301

    Base pan weldment diagram

    Shield Filte

    Part #D9821301

    The manufacturer no longer makes this part, and there's no substitute part

  • Screw-machin for Amana 9,000BTUMODELS - Part M0255014

    Screw-machin

    Part #M0255014

    The manufacturer no longer makes this part, and there's no substitute part

  • Overload for Amana 9,000BTUMODELS - Part D6961618

    Overload

    Part #D6961618

    The manufacturer no longer makes this part, and there's no substitute part

  • Panel for Amana 9,000BTUMODELS - Part D9813801

    Blower assembly diagram

    Panel

    Part #D9813801

    The manufacturer no longer makes this part, and there's no substitute part

  • Switch for Amana 9,000BTUMODELS - Part D9843001

    Top control panel diagram

    Switch

    Part #D9843001

    The manufacturer no longer makes this part, and there's no substitute part

Amana Ptac Package Terminal Air Conditioner 9,000BTUMODELS FAQs

A 9,000 BTU air conditioner typically cools about 300 to 400 square feet in an average room with standard ceiling height and normal sun exposure. For your Amana PTAC package terminal air conditioner model 9, the real coverage depends most on insulation, heat load, and airflow setup.

Typical 9,000 BTU coverage (quick guide)

Use these ranges as a practical starting point:

  • 300 to 400 sq ft: average bedroom, office, or studio area
  • 250 to 300 sq ft: hot, sunny rooms, poor insulation, lots of windows
  • 400 to 450 sq ft: shaded rooms, good insulation, limited foot traffic
  • Less coverage if the unit is in a high-heat space (kitchen-adjacent, west-facing, top floor)
Room conditions Typical 9,000 BTU coverage
Average (8 ft ceilings, normal sun) 300 to 400 sq ft
High heat load (sun, poor insulation) 250 to 300 sq ft
Low heat load (shaded, well insulated) 400 to 450 sq ft
What changes the square footage the most

Even with the same BTU rating, these factors can swing performance:

  • Ceiling height: ceilings above 8 ft reduce effective coverage
  • Sun exposure: large south or west windows increase heat load
  • Insulation and air leaks: drafts and weak insulation make the unit work harder
  • Occupancy and electronics: more people and equipment add heat
  • Airflow restrictions: dirty filters or blocked return air reduce cooling output
Why it matters

Sizing by square footage helps prevent short cycling (too large) or nonstop running (too small). A properly sized 9,000 BTU unit should maintain temperature steadily and manage humidity without running constantly.

Parts that can affect cooling performance

If the unit is not keeping up, basic maintenance and airflow checks come first. If you are servicing the cabinet or electrical connections, use the correct fasteners and hardware for reassembly, such as the frame screw WP693995 or terminal nut WP776338 when applicable.

Last updated: February 2026

For the Amana PTAC package terminal air conditioner model 9, the most common issues are poor cooling or airflow, water leaking into the room, unusual noise or vibration, and power or control problems. Many of these trace back to airflow restrictions, drainage problems, or loose electrical connections.

Most common symptoms and what usually causes them
  • Not cooling well: dirty filter or coils, blocked outdoor airflow, low refrigerant (sealed-system issue)
  • Weak airflow: clogged filter, blower wheel buildup, obstructed grille
  • Water leaking indoors: clogged drain path, unit not level, damaged or missing drain components
  • Rattling or vibration: loose chassis screws, fan contacting shroud, worn mounts
  • Won’t power on or trips breaker: loose wiring, failed capacitor/control, shorted component
Quick checks we recommend first (safe, no special tools)
  1. Set mode to Cool and temperature well below room temp; confirm the fan runs.
  2. Clean or replace the air filter; clear the front grille and return-air path.
  3. Inspect the drain area for slime or debris; flush if accessible.
  4. Verify the unit is slightly pitched to drain properly (typical PTAC requirement).
  5. Listen for where noise comes from (fan area vs. cabinet vs. electrical compartment).
Parts that commonly come up during PTAC service

These are small but important items that can affect noise, fit, and electrical reliability:

Issue you notice Part type that may be involved Example on this model page
Rattling cabinet or loose panels Frame/cabinet fasteners Frame screw WP693995
Loose electrical connection at a terminal Terminal hardware Terminal nut WP776338
General loose hardware Screws Screw WP90767
Why it matters

A PTAC that runs with restricted airflow or poor drainage can ice up, leak, or strain electrical components. Fixing the basic airflow, leveling, and fastener issues early helps restore cooling performance and prevents repeat failures.

Last updated: March 2026

For your Amana PTAC (package terminal air conditioner), the model number is printed on the unit’s rating label; it is usually inside the front grille area or on the side of the chassis. Use the full model number from that label when ordering parts for model 9.

Where to look on an Amana PTAC

Check these common rating-label locations (power off the unit first):

  • Behind the front cover or intake grille (often near the control box area)
  • On the side panel of the chassis (visible after removing the front cover)
  • Along the lower front frame rail, near the filter area
  • On the sleeve opening edge (sometimes visible when the chassis is partially slid out)
  • Near the electrical compartment cover (do not remove sealed covers)
What to write down (so parts match)

Record the full identification information exactly as shown on the label:

  • Model number (letters and numbers)
  • Serial number
  • Electrical ratings (volts and amps)
  • Cooling capacity (BTU)
Quick checklist
Label item Why it matters
Model number Ensures the correct parts list and diagrams
Serial number Helps confirm production version changes
Voltage Prevents ordering incompatible electrical parts
Why it matters

Amana PTAC units can look similar across different BTU sizes and production runs; the model number on the rating label is what ties your unit to the correct parts breakdown. If you are replacing hardware after opening the front panel, match fasteners by size and type, such as the frame screw WP693995.

Last updated: March 2026

Most common symptoms to help you fix your dishwashers

Choose a symptom to see related dishwasher repairs.

Main causes: light switch beside the sink turned off, lack of power, bad dishwasher door switch, control system failure,…

Main causes: damaged or stuck spray arm, leaking door seal, damaged door hinge, leaky heating element water seal, cracke…

Main causes: improper loading, low water temperature, improper detergent dosage, detergent dispenser failure, spray arm …

Main causes: glass or popcorn kernel stuck in the chopper blade, drain line vibrating against the cabinet, debris in was…

Main causes: broken door latch, tripped circuit breaker, broken heating element, faulty vent fan, sensor failure, contro…

Main causes: not using rinse aid, rinse aid dispenser failure, broken heating element, malfunctioning vent, drying fan f…

Main cause: damaged rack height adjuster…

Main causes: clogged kitchen sink drain, clogged drain hose, drain check valve damaged, drain pump failure, control syst…

Main causes: water supply problem, stuck overfill float, clogged water inlet valve screen, water inlet valve failure…

Most common repair guides to help fix your dishwashers

These step-by-step repair guides will help you safely fix what’s broken on your dishwasher.

How to replace a dishwasher door latch assembly

How to replace a dishwasher door latch assembly

If the dishwasher door doesn't click shut, a broken door latch is a likely cause. Follow these instructions to replace i…

Repair time and Difficulty

 30 minutes or less
How to replace a dishwasher thermal fuse

How to replace a dishwasher thermal fuse

A completely dead control panel often indicates that the thermal fuse on the electronic control board is blown; follow t…

Repair time and Difficulty

 15 minutes or less
How to replace a dishwasher control panel

How to replace a dishwasher control panel

Learn how to replace a dishwasher control panel. Learn which tools and parts you need and get step-by-step instructions.…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your dishwashers

Use the advice and tips in these articles and videos to get the most out of your dishwasher.

What's a turbidity sensor, and how does it affect wash quality?

What's a turbidity sensor, and how does it affect wash quality?

Your dishwasher’s secret weapon? A turbidity sensor. Find out what it does, how it boosts wash quality, and what to do i…

Dishwasher not drying dishes video

Dishwasher not drying dishes video

Find out why your dishes are still wet even after the dishwasher cycle has finished.…

Replacing dishrack rollers on Kenmore 587-series and Frigidaire dishwashers video

Replacing dishrack rollers on Kenmore 587-series and Frigidaire dishwashers video

It only takes a few minutes to get your dishrack sliding easily again.…

Parts & More

Bottom-Mount Refrigerator
Dishwasher
Dryer
Electric Cooktop
Front-Engine Lawn Tractor
Gas Range
Outdoor Grill
Range
Side-By-Side Refrigerator
Top-Mount Refrigerator
Washer