Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

Thermal Zone GM120K16B gas furnace Parts

Here are the diagrams and repair parts for Thermal Zone GM120K16B gas furnace, as well as links to manuals and error code tables, if available.

Thermal Zone GM120K16B gas furnace
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GM120K16B Gas Furnace

  • Switch for Thermal Zone GM120K16B - Part 632212

    80+ upflow furnace diagram

    Switch

    Part #632212

    The manufacturer no longer makes this part, and there's no substitute part

  • Motor for Thermal Zone GM120K16B - Part 902128

    80+ upflow furnace diagram

    Motor

    Part #902128

    The manufacturer no longer makes this part, and there's no substitute part

  • Switch for Thermal Zone GM120K16B - Part 632205

    80+ upflow furnace diagram

    Switch

    Part #632205

    The manufacturer no longer makes this part, and there's no substitute part

  • Vent Control Assembly for Thermal Zone GM120K16B - Part 372584

    80+ upflow furnace diagram

    Vent Control Assembly

    Part #372584

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Blower for Thermal Zone GM120K16B - Part 903111

    80+ upflow furnace diagram

    Furnace Blower

    Part #903111

    The manufacturer no longer makes this part, and there's no substitute part

  • Main Burner Ofrifice (43 Drill) (not Shown) for Thermal Zone GM120K16B - Part 661043

    80+ upflow furnace diagram

    Main Burner Ofrifice (43 Drill) (not Shown)

    Part #661043

    The manufacturer no longer makes this part, and there's no substitute part

  • Gasket, Collector Pan (not Shown) (replace Gasket Whenever Collector Pan Assembly (item 11) Is Removed) for Thermal Zone GM120K16B - Part 689359

    80+ upflow furnace diagram

    Gasket, Collector Pan (not Shown) (replace Gasket Whenever Collector Pan Assembly (item 11) Is Removed)

    Part #689359

    The manufacturer no longer makes this part, and there's no substitute part

  • Heat Exchanger for Thermal Zone GM120K16B - Part 493216

    80+ upflow furnace diagram

    Heat Exchanger

    Part #493216

    The manufacturer no longer makes this part, and there's no substitute part

  • Gasket, Collector Pan (not Shown) for Thermal Zone GM120K16B - Part 689072

    80+ upflow furnace diagram

    Gasket, Collector Pan (not Shown)

    Part #689072

    The manufacturer no longer makes this part, and there's no substitute part

  • Switch for Thermal Zone GM120K16B - Part 626350

    80+ upflow furnace diagram

    Switch

    Part #626350

    The manufacturer no longer makes this part, and there's no substitute part

Thermal Zone Gas Furnace GM120K16B FAQs

For a Thermal Zone gas furnace like model GM120K16B, the most common repairs involve ignition and flame sensing, airflow problems (filters, blower, or capacitor), and safety controls that stop heat when the furnace overheats or can’t prove flame. Many fixes start with basic checks before replacing parts.

Most common repairs we see

  • Replace a dirty air filter and clear blocked return or supply vents.
  • Clean the flame sensor (a common cause of short cycling and “starts then stops”).
  • Replace a weak run capacitor that prevents the blower motor from starting or running smoothly.
  • Replace a failed igniter or service the pilot/ignition system (depending on furnace design).
  • Clear a clogged condensate drain (on high-efficiency condensing furnaces).
  • Diagnose a tripped limit switch or rollout switch caused by overheating or venting issues.

Quick symptom-to-repair guide

What you notice Common cause Typical repair
Blower hums but won’t start Weak capacitor Replace capacitor 12908
Burner lights then shuts off quickly Dirty flame sensor Clean flame sensor, check grounding
Furnace runs but little airflow Dirty filter, blocked duct, blower issue Replace filter, check blower wheel and motor
No heat, no ignition Ignition component or control issue Check power, door switch, igniter, control board

Why it matters

Furnaces shut down on purpose when they detect unsafe conditions (no proven flame, overheating, blocked venting). Fixing the root cause protects the heat exchanger, improves comfort, and helps prevent repeat shutdowns.

Before you replace parts (safe, high-value checks)

  • Turn off power at the furnace switch or breaker before opening panels.
  • Confirm the thermostat is calling for heat and the furnace door switch is engaged.
  • Check and replace the air filter; verify vents are open.
  • Look for a blinking diagnostic light on the control board and note the pattern.
  • If you’re testing electrical parts, use a meter correctly; see how to use a multimeter to test electrical parts video.

Last updated: February 2026

In most gas furnaces, the heat exchanger is the most expensive component to replace because it requires the most disassembly and labor. On the Thermal Zone GM120K16B, the highest total repair cost still comes from major assemblies (heat exchanger, blower motor, inducer, or control board), not small electrical parts.

Most expensive furnace repairs (typical)

These repairs usually create the highest total bill (parts plus labor):

  • Heat exchanger replacement
  • Blower motor replacement (especially variable-speed/ECM styles)
  • Inducer motor assembly replacement
  • Furnace control board replacement
  • Gas valve replacement

What makes a repair “expensive”

Item Parts cost Labor time Why it adds up
Heat exchanger Medium to high Highest Major teardown and reassembly
Motors (blower/inducer) Medium to high Medium Setup, wiring, airflow or venting checks
Control board Medium to high Low to medium Diagnosis time, multiple failure look-alikes
Gas valve Medium Medium Combustion and safety verification

Check these lower-cost items first

Many “big repair” symptoms are caused by simpler issues. We recommend checking:

  • Dirty air filter or blocked return air causing overheating
  • Loose, burnt, or corroded wiring connections
  • Tripped breaker or blown furnace fuse
  • Furnace door switch not fully engaged
  • Weak motor run capacitor (can prevent a motor from starting)

If your GM120K16B uses a run capacitor in a motor circuit, the model-specific part listed for this furnace is the capacitor 12908.

Why it matters

Replacing a small, correct part first (like a capacitor) can restore operation and prevent unnecessary replacement of a motor or control board.

Last updated: February 2026

For your Thermal Zone gas furnace model GM120K16B, the best spare parts to keep on hand are the ones that commonly fail and can stop heat immediately, plus a few electrical items that are easy to test and replace. If you only stock one model-listed item, start with the capacitor 12908.

These are the most practical “down heat” spares for a typical gas furnace like the GM120K16B:

  • Hot surface ignitor (or spark ignitor, depending on your ignition style)
  • Flame sensor (cleaning often fixes issues, but replacement is a common need)
  • Furnace fuse(s) (typically a small automotive-style blade fuse on the control board)
  • Control board (more expensive, but a frequent no-heat culprit)
  • Pressure switch (proves draft; failures can lock out ignition)
  • Limit switch (safety device; can fail open and stop burners)
  • Blower motor run capacitor (supports the blower motor start/run)

What we can stock from this model’s parts list

Only one specific spare part is currently listed in the available parts for this model page:

Quick “what it does” guide

Spare part What it affects Common symptom when it fails
Ignitor Burner ignition No flame, repeated ignition attempts
Flame sensor Flame proving Burner lights then shuts off quickly
Fuse Low-voltage power Furnace appears dead, no response
Control board Furnace control logic No heat cycle, erratic operation
Capacitor Blower motor performance Hums, slow start, overheats, trips limit

How to choose the right spares

Use these checks so you buy parts that match your exact furnace configuration:

  • Match by model number GM120K16B and the part’s ID/part number
  • Compare the old part’s label ratings (especially capacitor microfarads (µF) and voltage)
  • Take a clear photo of wire locations before removing any electrical part
  • Keep spares sealed and dry; corrosion and bent terminals cause problems

Why it matters

A small set of spares can turn a “no-heat” situation into a same-day fix, especially for ignition and airflow safety parts that commonly stop the furnace from running.

Last updated: February 2026

Symptoms for gas snowblowers

Choose a symptom to see related snowblower repairs.

Main causes: stale gas, clogged carburetor, clogged or broken fuel line, dirty spark plug, bad rewind starter, incorrect…

Main causes: punctured tire, damaged rim…

Main causes: snow build-up in chute, chute drive mechanism failure, bad chute control assembly…

Main causes: clogged chute, damaged auger blades, broken shear pins, worn auger belt, damaged gear case, engine problems…

Things to do: replace the spark plug, change the oil, rebuild the carburetor, adjust valve lash, adjust or replace the b…

Main causes: dirty carburetor, stale fuel…

Main causes: clogged chute, snow build-up in auger housing, broken auger shear pins, auger drive belt needs adjustment, …

Main causes: broken shear pins, worn or loose auger drive belt, auger drive cable failure, damaged auger, bad gear case…

Main causes: loose drive clutch cable, damaged drive clutch cable, worn friction disc, scraper blade scraping the ground…

Repair guides for gas snowblowers

These step-by-step repair guides will help you safely fix what’s broken on your snowblower.

How to adjust snowblower skid shoes

How to adjust snowblower skid shoes

To prevent snowblower auger and shave plate damage, adjust the skid shoes regularly to keep the shave plate ¼-inch high.…

Repair time and Difficulty

 15 minutes or less
How to rebuild a snowblower carburetor

How to rebuild a snowblower carburetor

Rebuild the carburetor on your snowblower if the engine isn't getting fuel.…

Repair time and Difficulty

 45 minutes or less
How to replace a snowblower 4-way chute control assembly

How to replace a snowblower 4-way chute control assembly

Replace the 4-way chute control assembly on your snowblower if it’s damaged.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your furnaces

Use the advice and tips in these articles and videos to get the most out of your snowblower.

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Parts