ICP H9MPD075F12B1 90+ single-stage gas furnace

ICP H9MPD075F12B1 90+ single-stage gas furnace Parts

Here are the diagrams and repair parts for ICP H9MPD075F12B1 90+ single-stage gas furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for H9MPD075F12B1 90+ Single-Stage Gas Furnace

  • Coupling for ICP H9MPD075F12B1 - Part 1171993

    Furnace diagram

    Coupling

    In Stock
    $31.52
    Minus Item
    Qty
    Plus Item
  • Drain Trap for ICP H9MPD075F12B1 - Part 1171916

    Furnace diagram

    Drain Trap

    In Stock
    $54.70
    Minus Item
    Qty
    Plus Item
  • Coupling for ICP H9MPD075F12B1 - Part 1012284

    Furnace diagram

    Coupling

    In Stock
    $35.03
    Minus Item
    Qty
    Plus Item
  • Furnace Pilot Igniter And Sensor for ICP H9MPD075F12B1 - Part 1009524

    Furnace diagram

    Furnace Pilot Igniter And Sensor

    In Stock
    $206.97
    5% OFF Phone Price : $218.97Info Icon
    Minus Item
    Qty
    Plus Item
  • Tube Sensor for ICP H9MPD075F12B1 - Part 1006298

    Furnace diagram

    Tube Senso

    Part #1172239

    Replaced by #1006298

    Info Icon
    Manufacturer substitution
    This part replaces 1172239. Substitute parts can look different from the original.
    In Stock
    $27.57
    Minus Item
    Qty
    Plus Item
  • Tube Sensor for ICP H9MPD075F12B1 - Part 1006298

    Furnace diagram

    Tube Senso

    Part #1172012

    Replaced by #1006298

    Info Icon
    Manufacturer substitution
    This part replaces 1172012. Substitute parts can look different from the original.
    In Stock
    $27.57
    Minus Item
    Qty
    Plus Item
  • Tube Sensor for ICP H9MPD075F12B1 - Part 1006298

    Furnace diagram

    Tube Senso

    Part #1172240

    Replaced by #1006298

    Info Icon
    Manufacturer substitution
    This part replaces 1172240. Substitute parts can look different from the original.
    In Stock
    $27.57
    Minus Item
    Qty
    Plus Item
  • Kit Drain for ICP H9MPD075F12B1 - Part 1177835

    Furnace diagram

    Tee Drain

    Part #1171915

    Replaced by #1177835

    Info Icon
    Manufacturer substitution
    This part replaces 1171915. Substitute parts can look different from the original.
    In Stock
    $109.07
    Minus Item
    Qty
    Plus Item
  • Icp Furnace Inducer Vent Motor Assembly for ICP H9MPD075F12B1 - Part 1172823

    Furnace diagram

    Furnace Blower Vent

    Part #1014338

    Replaced by #1172823

    Info Icon
    Manufacturer substitution
    This part replaces 1014338. Substitute parts can look different from the original.
    In Stock
    $313.01
    $12.00 OFF Phone Price : $325.01Info Icon
    Minus Item
    Qty
    Plus Item
  • Door Front for ICP H9MPD075F12B1 - Part 1014265

    Furnace diagram

    Door Front

    Part #1014265

    The manufacturer no longer makes this part, and there's no substitute part

ICP 90+ Single-Stage Gas Furnace H9MPD075F12B1 FAQs

On the Icp H9MPD075F12B1 90+ single-stage gas furnace, the most common failure item is the hot surface igniter (or the igniter-sensor assembly), because it heats to very high temperatures on every call for heat and becomes brittle over time. Confirm the exact ignition style and service steps in the H9MPD075F12B1 owner's manual.

What typically fails first (and what you notice)

In real-world furnace troubleshooting, these parts cause the most no-heat calls:

  • Igniter or igniter/sensor: furnace tries to start, then shuts down; no flame.
  • Flame sensor: burners light briefly, then go out after a few seconds.
  • Pressure switch or tubing: inducer runs but ignition never completes; venting/condensate issues can contribute.
  • Air filter: restricted airflow leads to overheating and shutdown; dirty filters are a very common cause of inadequate heating performance.
  • Limit switch: furnace cycles on and off, or shuts down on high temperature.

Quick checks we recommend before replacing parts

Turn off electrical power before removing panels or doing any maintenance.

  • Check and replace the air filter; inspect it monthly and replace before it clogs.
  • Make sure the furnace area is clean and clear of combustibles and loose insulation.
  • Verify the return air duct connection is sealed and physically sound.
  • If overheating occurs, shut off the gas valve before shutting off electrical power.
  • Look for cracked or loose pressure-switch tubing during yearly maintenance.

Common symptoms and likely causes

Symptom Most likely cause What to do next
No glow at igniter, no flame Igniter failed or no power to igniter Test igniter circuit; replace igniter if open
Flame lights then drops out Flame sensor dirty/weak Clean sensor; replace if problem returns
Inducer runs, then stops, no ignition Pressure switch not closing Check venting, condensate drain, and tubing
Short cycling, hot smell, shuts off Airflow restriction or limit opening Replace filter; check blower and ducts

Parts that commonly solve “no heat” on this model

If your diagnosis points to ignition, these are the most relevant model-listed parts:

Why it matters

Replacing the right part first prevents repeat shutdowns, protects the heat exchanger from overheating, and restores safe, reliable ignition. Airflow basics (filter and return duct sealing) also reduce nuisance limit trips and poor heating performance.

Last updated: February 2026

In most gas furnaces, the heat exchanger is the most expensive component to replace because it is labor-intensive and central to safe heating. On the Icp H9MPD075F12B1 (a 90+ single-stage gas furnace), other high-cost repairs commonly include the inducer assembly, blower motor, and gas valve; see the H9MPD075F12B1 owner's manual for model-specific component and maintenance guidance.

Typical “most expensive” furnace parts (what we see most often)

Costs vary by brand, access, and labor time, but these are the usual top-ticket items:

  • Heat exchanger (often the highest total repair cost)
  • Inducer/vent motor assembly (draft/combustion blower)
  • Blower fan motor (circulating air)
  • Gas valve
  • Control board (if equipped)

Quick cost comparison (parts + labor ranges)

These are typical residential ranges to help set expectations.

Part or assembly Why it gets expensive Typical total cost range
Heat exchanger Major disassembly, long labor time $1,500 to $4,000
Inducer/vent motor Sealed combustion parts, diagnostics $600 to $1,500
Blower fan motor Motor + setup, sometimes wheel/balance $500 to $1,400
Gas valve Safety-critical, setup and testing $400 to $1,200
Control board Electrical diagnosis, programming/setup $300 to $900

Model-specific notes for Icp H9MPD075F12B1

For this model, some of the higher-priced parts we commonly see customers replace include:

Why it matters

When a repair approaches the cost of a major assembly, it is smart to confirm the diagnosis first. Simple maintenance can also prevent expensive failures; the manual notes that dirty or overly restrictive filters can raise operating temperatures and shorten furnace life.

What we recommend before approving a big repair

  • Check the filter type and condition; replace or clean it on schedule
  • Verify the furnace is getting proper airflow (return grilles open, no blocked supply vents)
  • Confirm the fault code or symptom matches the suspected part
  • If testing electrical components, use safe meter practices
  • For gas or combustion-related repairs (heat exchanger, gas valve, inducer), use a qualified technician

Last updated: February 2026

A high-efficiency (90+ AFUE) gas furnace like the Icp H9MPD075F12B1 uses a sealed combustion and venting system plus standard heating components: burners and ignition to light gas, a heat exchanger to transfer heat, safety switches to prove safe operation, and a blower to move warm air through your ducts. See the H9MPD075F12B1 owner's manual for your unit’s exact component locations.

Core parts and what they do

  • Burners: mix gas and air to create a stable flame.
  • Ignition system: lights the burners (hot surface igniter or pilot-style ignition module, depending on configuration).
  • Heat exchanger: transfers heat from combustion to household air.
  • Inducer (venter) assembly: pulls combustion air and pushes flue gases through the vent system.
  • Pressure switch(es): confirm proper draft before allowing ignition.
  • Main gas control valve: opens and closes gas flow to the burners.
  • Circulating blower motor and wheel: moves heated air through the ductwork.
  • Temperature limit switch: shuts the burners off if the furnace overheats.
  • Door switch: prevents operation when the blower door is off.

Model-relevant examples of parts we stock for H9MPD075F12B1

Function Example part for this model What you’ll notice when it fails
Prove flame / ignition sensing Furnace pilot igniter and sensor 1009524 No heat, short cycling, ignition tries then stops
Move combustion gases (draft) Furnace blower vent 1172823 Inducer won’t run, pressure switch won’t close
Move house air Furnace blower fan motor, 1/2-hp 1013341 Weak airflow, blower won’t start, overheating
Control gas flow Gas valve SV9641M4510 No ignition, no flame, intermittent heat
Prevent overheating Furnace temperature limit switch 1013102 Burners shut off quickly, blower runs longer

Why it matters (efficiency and safety)

High-efficiency furnaces rely on correct combustion air and venting. We recommend keeping the furnace area clear, never blocking air openings or ducts, and turning off gas and electrical power before any service. A qualified service check before each heating season helps keep operation safe and efficient.

Quick homeowner checks (no disassembly)

  • Confirm the thermostat is calling for heat and the furnace has power.
  • Make sure the blower door is fully seated (door switch must be engaged).
  • Replace or clean the air filter regularly to prevent overheating.
  • Check that venting and flue-gas pathways are clear and unobstructed.
  • If the furnace has been exposed to water, stop using it and have it inspected by a qualified service agency.

Last updated: February 2026

Repair guides for side-by-side refrigerators

How to replace an electronic control board on the back of a refrigerator

How to replace an electronic control board on the back of a refrigerator

If your refrigerator isn't running, an electronic control board failure could be the problem. A service technician can d…

Repair time and Difficulty

 15 minutes or less
How to replace a press-in door gasket in a side-by-side refrigerator

How to replace a press-in door gasket in a side-by-side refrigerator

The door gasket seals the gap around the door to keep the cold air in and the warm air out. Replace a worn or damaged do…

Repair time and Difficulty

 15 minutes or less
How to replace an ice maker in a side-by-side refrigerator

How to replace an ice maker in a side-by-side refrigerator

Learn how to replace the ice maker in a side-by-side refrigerator with these step-by-step instructions.…

Repair time and Difficulty

 30 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Air Purifier
Central Air Conditioner
Countertop Microwave
Gas Snowblower
Miter Saw
Parts
Stepper
Washer