Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Rheem GUC gas-fired horizontal heating unit

Rheem GUC gas-fired horizontal heating unit Parts

Here are the diagrams and repair parts for Rheem GUC gas-fired horizontal heating unit, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GUC Gas-Fired Horizontal Heating Unit

  • Blower Wheel for Rheem GUC - Part 70-20218-02

    #NI

    All parts diagram

    Furnace Blower Wheel

    Part #70-18621-01

    Replaced by #70-20218-02

    Info Icon
    Manufacturer substitution
    This part replaces 70-18621-01. Substitute parts can look different from the original.
    In Stock
    $268.61
    Minus Item
    Qty
    Plus Item
  • 1/6-1/2 Hp M for Rheem GUC - Part 45460

    #NI

    All parts diagram

    Motor

    Part #51-19923-01

    Replaced by #45460

    Info Icon
    Manufacturer substitution
    This part replaces 51-19923-01. Substitute parts can look different from the original.
    In Stock
    $280.82
    Minus Item
    Qty
    Plus Item
  • Ign Cabl Kit for Rheem GUC - Part 45-21219-82

    Replacement parts diagram

    Ignton Cble

    Part #45-21219-02

    Replaced by #45-21219-82

    Info Icon
    Manufacturer substitution
    This part replaces 45-21219-02. Substitute parts can look different from the original.
    In Stock
    $302.88
    Minus Item
    Qty
    Plus Item
  • Brnr Stanlss for Rheem GUC - Part 75-21583-02

    Replacement parts diagram

    Burner

    Part #75-20735-04

    Replaced by #75-21583-02

    Info Icon
    Manufacturer substitution
    This part replaces 75-20735-04. Substitute parts can look different from the original.
    In Stock
    $107.54
    Minus Item
    Qty
    Plus Item
  • Front Panel for Rheem GUC - Part AS-63397-03

    Replacement parts diagram

    Front Panel

    Part #AS-63397-03

    The manufacturer no longer makes this part, and there's no substitute part

  • Rear Panel for Rheem GUC - Part AS-63397-04

    Replacement parts diagram

    Rear Panel

    Part #AS-63397-04

    The manufacturer no longer makes this part, and there's no substitute part

  • Manifold for Rheem GUC - Part AS-63405-07

    Replacement parts diagram

    Manifold

    Part #AS-63405-07

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Blower Housing for Rheem GUC - Part AS-63265-02

    #NI

    All parts diagram

    Furnace Blower Housing

    Part #AS-63265-02

    The manufacturer no longer makes this part, and there's no substitute part

  • Furnace Blower Housing for Rheem GUC - Part AS-63264-06

    #NI

    All parts diagram

    Furnace Blower Housing

    Part #AS-63264-06

    The manufacturer no longer makes this part, and there's no substitute part

  • Tray Assembly for Rheem GUC - Part AS-63448-06

    Replacement parts diagram

    Tray Assembly

    Part #AS-63448-06

    The manufacturer no longer makes this part, and there's no substitute part

Rheem Gas-Fired Horizontal Heating Unit GUC FAQs

For a Rheem GUC gas-fired horizontal heating unit, an “ignitor reset” is usually done by safely cycling power to clear a soft lockout, then correcting the cause (dirty flame sensor, airflow problem, weak draft). If the furnace locks out again, troubleshoot the ignition sequence instead of repeatedly resetting.

Safe reset steps (power-cycle reset)

  • Set the thermostat to OFF.
  • Turn OFF furnace power at the switch or breaker.
  • Wait 3 to 5 minutes (lets the control board fully reset).
  • Turn power ON.
  • Set the thermostat to HEAT and raise the setpoint.
  • Watch one full cycle: inducer starts, ignitor heats, gas valve opens, burners light, blower starts.

What to check if it won’t relight after the reset

Most ignition failures come from one of these conditions:

  • No power to the furnace (tripped breaker, door switch not engaged).
  • No gas (manual shutoff closed, gas supply interruption).
  • Dirty flame sensor (burners light then shut off within seconds).
  • Airflow restriction (dirty filter, blocked return, closed registers) causing a limit trip.
  • Weak blower start (bad run capacitor or failing motor).

Quick symptom guide

What you see Most common cause What we do next
Ignitor never glows Control, safety switch, wiring Verify power, door switch, safeties; test voltage
Ignitor glows, no flame Gas valve not opening, gas off Confirm gas supply; check for valve voltage
Flame starts then stops fast Flame sensor dirty Clean sensor; verify grounding
Runs then shuts down hot Overheat/limit trip Check filter, vents, blower wheel, capacitor

Parts that commonly relate to ignition and shutdown issues

If testing points to a failed component, match by model and rating before ordering:

Why it matters

Repeated resets can mask a safety shutdown (limit trip or flame-sense failure). A correct reset plus a quick check of airflow, flame sensing, and blower performance prevents nuisance lockouts and protects the heat exchanger and control board.

Last updated: February 2026

Most Rheem furnaces, including the Rheem GUC gas-fired horizontal heating unit, last 15 to 20 years on average. With consistent maintenance and correct airflow, it’s common to reach the high end of that range; neglected filters and overheating shorten service life.

What affects furnace lifespan the most

  • Annual maintenance: cleaning, combustion check, and safety inspection
  • Airflow and filtration: a clogged filter overheats the heat exchanger
  • Duct condition: restrictions make the blower work harder
  • Electrical health: weak capacitors and loose wiring stress motors and controls
  • Run time and sizing: oversized units short-cycle; undersized units run constantly

Quick maintenance checklist (high impact)

  • Replace or clean the air filter on a regular schedule (often every 1 to 3 months)
  • Keep supply and return vents open and unobstructed
  • Vacuum dust around the blower compartment and burner area (power off)
  • Confirm the thermostat cycles normally (no rapid on-off)
  • Have a technician check temperature rise and combustion annually

Typical lifespan ranges (what to expect)

Condition Typical lifespan What you’ll notice
Well maintained 18 to 25 years steady heat, fewer shutdowns
Average maintenance 15 to 20 years occasional repairs over time
Poor maintenance 10 to 15 years overheating, noisy blower, frequent cycling

Why it matters

A furnace near the end of its expected life is more likely to develop airflow and ignition problems that reduce comfort and efficiency. Replacing common wear items early can prevent bigger failures; for example, a weak run capacitor can strain the blower motor, so checking parts like the capacitor 12907 helps protect the system.

Last updated: February 2026

For a Rheem GUC gas-fired horizontal heating unit replacement, most homeowners in the U.S. typically spend about $3,800 to $10,000 installed, with many projects landing near $7,000 for an average-size home. Final price depends most on furnace size, efficiency rating, and installation complexity.

What drives the installed price most

  • Furnace capacity (BTU output): larger homes need larger units.
  • Efficiency (AFUE): higher-efficiency models cost more up front.
  • Venting changes: switching vent type or routing can add labor and materials.
  • Ductwork condition: repairs, resizing, or sealing increases cost.
  • Electrical and controls: adding a new disconnect, thermostat, or wiring updates can add cost.
  • Permits and inspections: commonly required for gas appliances.

Typical cost ranges (installed)

What you’re paying for Typical range Notes
Furnace equipment only $1,500 to $5,500 Varies by brand, size, AFUE, and features
Labor and installation $2,000 to $6,000 Higher when venting or ductwork needs changes
Total installed project $3,800 to $10,000 Many replacements cluster around ~$7,000

Quick ways to keep the quote accurate

  • Match the quote to your exact model and configuration (horizontal vs. upflow).
  • Ask whether the bid includes venting, condensate drain work (if applicable), and duct transitions.
  • Confirm permit and inspection costs are included.
  • Verify the contractor is sizing the furnace (not just copying the old BTU rating).

Why it matters

A furnace that is oversized, undersized, or installed with incorrect venting can cycle poorly, waste fuel, and shorten component life (blower motor, capacitor, and limit controls). If you’re repairing instead of replacing, pricing out key components like the motor 45460 can help you compare repair cost vs. replacement.

Last updated: February 2026

The most common Rheem furnace “error” is an ignition or flame-proving failure, where the burners light briefly (or not at all) and the control board shuts the heat down for safety. On Rheem GUC gas-fired horizontal heating units, this is most often tied to dirty flame sensing, restricted airflow, or a draft/pressure-switch proving problem.

What you’ll usually see (symptoms)

  • Furnace starts, then stops and retries several times
  • Blower runs but no heat
  • Short cycling (heat runs briefly, then shuts off)
  • Status light blinking a repeating pattern on the control board
  • “No heat” after a filter change or after vents were closed

Quick checks we recommend before replacing parts

  1. Replace the air filter and make sure supply registers are open.
  2. Confirm the thermostat is calling for heat (set to HEAT, temperature raised).
  3. Check intake and exhaust venting for blockage (snow, nests, debris, sagging hose on high-efficiency setups).
  4. Power-cycle the furnace (turn switch off for 30 seconds, then on) and watch the ignition sequence.
  5. If you’re comfortable testing, use a meter to verify safe voltage and continuity; follow how to use a multimeter to test electrical parts video.

Common causes and what they point to

What’s happening Most likely cause What to do next
Igniter glows, burners light, then shut off in seconds Dirty flame sensor or poor grounding Clean flame sensor; check ground connections
Burners never light, inducer runs Pressure switch not proving draft Check venting, condensate drain (if applicable), tubing
Furnace overheats, then shuts down Airflow restriction or limit switch opening Replace filter, open vents, check blower wheel
Blower hums or struggles to start Weak run capacitor Test/replace capacitor 12907

Why it matters

Ignition and pressure-switch related shutdowns are safety lockouts; the furnace is preventing raw gas buildup or overheating. Fixing airflow and basic proving issues first avoids unnecessary part replacement and repeat lockouts.

Last updated: February 2026

On a Rheem GUC gas-fired horizontal heating unit, the model number is typically printed on the furnace rating plate (data tag) inside the front access panel, usually near the burner compartment or blower area. We recommend matching the full model number exactly before ordering parts.

Where to look on the furnace

  • Turn the thermostat OFF so the furnace is not calling for heat.
  • Shut off power at the furnace switch or breaker.
  • Remove the front access panel (upper and or lower door, depending on cabinet style).
  • Look for a silver or white rating plate with “Model” and “Serial” fields.
  • Check common tag locations:
    • Inside the upper burner compartment
    • Inside the blower compartment near the blower housing
    • On an interior side wall of the cabinet

What to write down (so parts match)

Record the information exactly as shown on the tag.

Item on tag What it’s used for Example format
Model number Identifies the correct parts list GUC… (letters and numbers)
Serial number Helps identify production details Alphanumeric string
Input and fuel Confirms gas type and capacity Natural gas, BTU input

Why it matters

Rheem furnaces often have similar cabinet styles across multiple series; the exact model number ensures the right fit for components like a blower motor capacitor, limit switch, or blower wheel.

If you are ordering a motor run capacitor for this unit, match the tag information first and then compare it to the specs on the part listing for the capacitor 12907.

Last updated: February 2026

Repair guides for front-engine lawn tractors

How to replace a blade clutch cable on a riding lawn mower

How to replace a blade clutch cable on a riding lawn mower

If the blades don't spin on your riding mower when you shift the lever, the blade clutch cable could be broken. Here’s h…

Repair time and Difficulty

 30 minutes or less
How to replace a ground drive belt on a riding lawn mower

How to replace a ground drive belt on a riding lawn mower

Replace the ground drive belt if it's broken or too worn to spin the transaxle pulley.…

Repair time and Difficulty

 45 minutes or less
How to replace a riding lawn mower blade drive belt

How to replace a riding lawn mower blade drive belt

Replace the blade drive belt if it's broken or won't spin the cutting blades because of wear.…

Repair time and Difficulty

 45 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Parts