Goodman GMNT100-4B gas furnace

Goodman GMNT100-4B gas furnace Parts

Here are the diagrams and repair parts for Goodman GMNT100-4B gas furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for GMNT100-4B Gas Furnace

  • Furnace Secondary Heat Exchanger for Goodman GMNT100-4B - Part 2864605S

    Heat exchanger assembly diagram

    Furnace Secondary Heat Exchanger

    In Stock
    $619.67
    $12.00 OFF Phone Price : $631.67Info Icon
    Minus Item
    Qty
    Plus Item
  • Burner Rack for Goodman GMNT100-4B - Part 0121F00157

    Burner box assembly diagram

    Rack

    Part #2513501

    Replaced by #0121F00157

    Info Icon
    Manufacturer substitution
    This part replaces 2513501. Substitute parts can look different from the original.
    In Stock
    $34.90
    Minus Item
    Qty
    Plus Item
  • Furnace Inducer Vent Motor Assembly for Goodman GMNT100-4B - Part B4833000S

    Heat exchanger assembly diagram

    Vent Motor

    Part #B4833000

    Replaced by #B4833000S

    Info Icon
    Manufacturer substitution
    This part replaces B4833000. Substitute parts can look different from the original.
    In Stock
    $437.24
    $12.00 OFF Phone Price : $449.24Info Icon
    Minus Item
    Qty
    Plus Item
  • Furnace Blower Fan Motor Housing for Goodman GMNT100-4B - Part 2539305S

    Blower assembly diagram

    Shell

    Part #2539305

    Replaced by #2539305S

    Info Icon
    Manufacturer substitution
    This part replaces 2539305. Substitute parts can look different from the original.
    In Stock
    $118.16
    9% OFF Phone Price : $130.16Info Icon
    Minus Item
    Qty
    Plus Item
  • Burner for Goodman GMNT100-4B - Part 0121F00146

    Burner box assembly diagram

    Side

    Part #2514000

    Replaced by #0121F00146

    Info Icon
    Manufacturer substitution
    This part replaces 2514000. Substitute parts can look different from the original.
    In Stock
    $24.40
    Minus Item
    Qty
    Plus Item
  • Goodman Blw Mtr Psc 1/2hp 1130rpm 115v for Goodman GMNT100-4B - Part 0131F00042SP

    Blower assembly diagram

    Furnace Blower Fan Motor

    Part #0131F00022

    Replaced by #0131F00042SP

    Info Icon
    Manufacturer substitution
    This part replaces 0131F00022. Substitute parts can look different from the original.
    In Stock
    $422.68
    Minus Item
    Qty
    Plus Item
  • Burner Rck for Goodman GMNT100-4B - Part 0121F00159

    Burner box assembly diagram

    Rack

    Part #2513503

    Replaced by #0121F00159

    Info Icon
    Manufacturer substitution
    This part replaces 2513503. Substitute parts can look different from the original.
    In Stock
    $116.86
    Minus Item
    Qty
    Plus Item
  • Manifold, Gas 2 Cl (gmt045-3b, Gdt045-3b, Gmth045-3b) for Goodman GMNT100-4B - Part B4026005

    Burner box assembly diagram

    Manifold, Gas 2 Cl (gmt045-3b, Gdt045-3b, Gmth045-3b)

    Part #B4026005

    The manufacturer no longer makes this part, and there's no substitute part

  • Door-blwr for Goodman GMNT100-4B - Part 2515009

    Wrapper assembly diagram

    Door-blwr

    Part #2515009

    The manufacturer no longer makes this part, and there's no substitute part

  • Primary Limit Switch, 190f (gmth045-3b) for Goodman GMNT100-4B - Part B1370199

    Heat exchanger assembly diagram

    Primary Limit Switch, 190f (gmth045-3b)

    Part #B1370199

    The manufacturer no longer makes this part, and there's no substitute part

Goodman Gas Furnace GMNT100-4B FAQs

For your Goodman GMNT100-4B gas furnace, the “size” is typically the heating capacity (input in BTU/hr). The most accurate way to confirm it is to read the series and rating plate on the furnace cabinet and match it to the specifications in the owner's manual.

What “size” means for a furnace

Furnace size is usually discussed in BTU/hr, not tons (tons is commonly used for air conditioners and heat pumps). You may see:

  • Input BTU/hr (gas burned)
  • Output BTU/hr (heat delivered after efficiency losses)
  • Airflow (CFM) and temperature rise ranges

Where to find the size on a Goodman GMNT100-4B

Check these common locations:

  • The series and rating plate (often inside the blower door or on the cabinet side)
  • The model/serial data sticker on the furnace
  • The specification section in the owner's manual

Quick checks that help confirm you are reading the right number

Use these tips so you do not confuse capacity with other specs:

  • Look for wording like “Input” or “BTU/hr”
  • Do not use motor HP, voltage, or amp ratings as “size”
  • If your home is at higher elevation, the effective input can be lower after derating

Altitude note (important)

For installations above 2,000 feet, the manual explains that furnaces are typically derated 4% per 1,000 feet above sea level and may require an orifice change. That means the rating plate input is the starting point, but the actual firing rate can be adjusted for altitude.

Common “size” terms at a glance

Term you see What it tells you Where to look
Input (BTU/hr) Gas input rating Rating plate, manual
Output (BTU/hr) Delivered heat Manual/spec sheet
Temperature rise Proper heating range Manual

Why it matters

Correct furnace sizing helps prevent short cycling, comfort problems, and overheating conditions that can trip safety limits. It also helps you choose the right replacement parts when troubleshooting ignition, venting, or airflow issues.

Last updated: February 2026

On the Goodman GMNT100-4B gas furnace, a “pressure switch stuck open” condition almost always means the furnace is not proving draft because of a vent restriction, condensate/drain issue, or an inducer (venter) problem. We fix it by restoring proper airflow through the venting and confirming the inducer creates enough negative pressure to close the switch.

Safety first

  • Turn off electrical power to the furnace at the service switch or breaker.
  • Shut off the gas supply if you will be opening the burner compartment.
  • Let the furnace cool before touching the inducer housing or vent pipe.
  • Keep the blower door installed; the door interlock shuts the furnace down when the door is off.

What to check (in order)

  1. Vent and intake piping: Look for snow, leaves, nests, sagging pipe, or a blocked termination.
  2. Pressure switch hose: Remove the hose and clear water, cracks, soft spots, or kinks; re-seat it firmly.
  3. Condensate drain (if equipped): Clear clogs and standing water that can back up into the pressure tubing/collector box.
  4. Inducer (venter) operation: On a call for heat, the inducer should start and run smoothly; scraping, slow start, or stalling points to a failing inducer.
  5. Electrical connections: Verify the spade terminals at the pressure switch and control board are tight and not corroded.

Quick functional checks from the manual

The GMNT100-4B uses a vent pressure switch to prevent operation if the vent is restricted or the venter fails. A simple check is to run the furnace and remove the hose from the switch; the burners should go out, and reinstalling the hose should allow normal operation (once draft is proven). Use the owner's manual for the exact sequence and status light behavior.

Common fixes and when to replace parts

Symptom Most likely cause What we do next
Inducer runs, switch never closes Vent restriction or water in hose Clear vent, drain, and tubing
Inducer noisy or won’t reach speed Failing inducer motor Replace inducer assembly
Hose and vent clear, wiring good Weak/failed pressure switch Replace pressure switch

If the inducer is the issue, the model-specific replacement is the motor 0131M00002PSP. If the switch itself is faulty, use the furnace air pressure switch B1370176.

Why it matters

The pressure switch is a safety device; it stops burner operation when the furnace cannot vent combustion gases correctly. Fixing the underlying draft or drainage problem restores safe ignition and prevents nuisance shutdowns.

Last updated: February 2026

On the Goodman GMNT100-4B gas furnace, code 4 (four status light flashes) means the control detected an open main limit (high-temperature limit) switch. The furnace stops heating until the limit closes; during an open-limit condition, the control energizes the circulating blower (see the owner's manual).

What usually causes a 4-flash limit code

An open limit is an overheating protection response; airflow problems are the most common trigger.

  • Dirty or restrictive air filter
  • Supply registers closed, blocked, or undersized
  • Return air grilles blocked (starving the blower)
  • Blower wheel packed with dust or slipping on the shaft
  • Blower motor not running at the correct speed
  • Limit switch wiring loose, damaged, or the switch is weak

What we recommend you check first (safe, homeowner-level)

Shut off power to the furnace at the switch or breaker before inspecting anything.

  • Replace the filter with the correct size and type
  • Open all supply registers; clear obstructions from return grilles
  • Make sure the blower door is fully seated (the door interlock must be engaged)
  • Check for obvious duct restrictions (collapsed flex duct, closed dampers)
  • After the furnace cools, restore power and call for heat to see if the code returns

Parts that commonly relate to a 4-flash limit issue

If airflow is correct and the code repeats, these parts are commonly involved on this model.

What you observe What it points to Example GMNT100-4B part
Heat starts, then shuts off; blower keeps running Limit opening from overheating Furnace temperature limit switch B1370198
Blower is weak or noisy; poor airflow Blower wheel or motor issue Blower fan wheel D6723311S
Erratic operation or repeated fault behavior Control board monitoring/logic Furnace hot-surface ignition control board B1809913S

Why it matters

The limit switch is a safety device. Correcting the airflow restriction or replacing the failed limit-related component prevents repeated shutdowns and helps protect the heat exchanger.

Last updated: February 2026

Symptoms for gas ranges

Main causes: gas supply problem, faulty pressure regulator, clogs in burner or orifice, control system failure, faulty t…

Main causes: burner igniter switch failure, bad spark module, dirty or damaged spark electrode, wiring failure…

Repair guides for gas ranges

How to replace a gas range oven igniter

How to replace a gas range oven igniter

If your gas oven doesn't heat up, the problem could be a faulty oven igniter. These step-by-step instructions guide you …

Repair time and Difficulty

 45 minutes or less
How to replace an oven temperature sensor on a gas range

How to replace an oven temperature sensor on a gas range

See how to replace an oven temperature sensor on a gas range.…

Repair time and Difficulty

 15 minutes or less
How to replace a gas range oven control board

How to replace a gas range oven control board

These step-by-step instructions explain how to replace an oven control board on a gas range…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your furnaces

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Boating
Bottom-Mount Refrigerator
Electric Range
Grass Catcher Attachment
Microwave/Hood Combo
Parts
Side-By-Side Refrigerator
Top-Mount Refrigerator
Treadmill
Washer