Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
ICP N9MPD075F12A2 90+ single-stage gas furnace

ICP N9MPD075F12A2 90+ single-stage gas furnace Parts

Here are the diagrams and repair parts for ICP N9MPD075F12A2 90+ single-stage gas furnace, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for N9MPD075F12A2 90+ Single-Stage Gas Furnace

ICP 90+ Single-Stage Gas Furnace N9MPD075F12A2 FAQs

The most common repairs on an Icp N9MPD075F12A2 90+ single-stage gas furnace involve ignition and safety shutoff issues (igniter, flame sensing, limit switch), airflow problems (dirty filter, blower issues), and control or venting problems (control board, inducer). Annual inspection before heating season helps prevent many of these failures; see the installation guide.

Common repairs we see most often

  • Replace a failed hot surface igniter (no ignition, repeated tries)
  • Clean or replace a dirty flame sensor (burners light then shut off)
  • Address overheating and shutdowns (restricted airflow, limit switch trips)
  • Repair venting or draft problems (inducer motor issues, pressure-related shutdowns)
  • Diagnose no-heat or intermittent heat caused by controls or wiring

Parts on this model that often relate to these repairs

If symptoms match, these are common replacement parts for N9MPD075F12A2:

Quick symptom-to-likely-cause guide

Symptom What it usually points to What to check first
Blower runs, no heat Ignition or flame proving issue Igniter glow, flame sensor condition
Burners light then shut off Flame sensor not proving flame Clean sensor, check grounding
Furnace shuts down, then restarts later Overheat protection tripping Filter, supply registers, blower wheel
Draft motor runs but no ignition Inducer/pressure/venting issue Intake/exhaust blockage, inducer operation
Completely dead Power, door switch, control issue Breaker, door switch, control board status

Why it matters (safety and reliability)

This furnace uses multiple safety devices designed to shut the system down under unsafe conditions; when a safety opens, the furnace can stop heating and may not restart until the issue is corrected. We also follow the guidance to have the furnace inspected and serviced annually (before the heating season) by a qualified service technician.

Safety notes we follow before any repair

  • Turn off electrical power at the service panel before servicing
  • Shut off the gas supply at the manual valve before working on gas components
  • Wear gloves and eye protection; sheet metal edges can be sharp
  • Use only the approved gas type shown on the rating plate

For ordering, you can buy replacement parts for N9MPD075F12A2 from the parts list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

On an Icp N9MPD075F12A2 90+ single-stage gas furnace, the most expensive repair is typically a major component replacement, most often the blower motor or the electronic control board. Heat exchanger-related repairs are also among the costliest because they involve extensive labor and critical safety checks (see the installation guide).

Most expensive furnace repairs (what usually drives the bill)

These repairs cost the most because they combine high-priced parts with longer diagnostic and installation time.

  • Heat exchanger related repair or replacement (labor-intensive and safety-critical)
  • Blower motor replacement (your model’s blower motor is a high-cost component)
  • Electronic control board replacement (a common high-dollar electrical repair)
  • Inducer vent motor assembly replacement (affects venting and safe ignition)
  • Repeated limit trips that trace back to airflow problems (can lead to multiple parts and labor)

High-cost parts we commonly see on this model

Here are examples of expensive, model-relevant parts listed for the N9MPD075F12A2.

Component What it does Example part on this model
Blower motor Moves heated air through the ductwork Mtr blr 1013341
Electronic control board Controls ignition sequence, blower timing, safeties Icp furnace electronic control board 1172550
Inducer vent motor assembly Pulls combustion gases through the vent system Icp furnace inducer vent motor assembly 1172823

Why “heat exchanger” repairs are usually the most expensive

The heat exchanger sits at the center of combustion and venting safety. Your installation instructions emphasize correct gas type, avoiding overfiring, and proper venting to the outdoors, all of which directly protect the heat exchanger and safe operation. When a heat exchanger issue is suspected, the repair process typically includes more inspection, setup, and verification steps than a simple part swap.

How to reduce the chance of a big repair

These steps prevent the most common causes of expensive failures (overheating, poor airflow, and ignition stress).

  • Replace the furnace filter on schedule to keep airflow strong
  • Keep supply and return vents open and unobstructed
  • Maintain proper clearances for service access (your guide calls out front clearance for servicing)
  • Address short-cycling and repeated limit trips early (often airflow-related)
  • If you’re ordering parts, match by model number N9MPD075F12A2 and part ID; you can also search on Sears PartsDirect

Last updated: February 2026

For the Icp N9MPD075F12A2 90+ single-stage gas furnace, replacement cost depends on the exact part and labor. Many common parts cost tens to a few hundred dollars; larger assemblies (like motors) cost more. Total installed cost rises most with diagnosis time and access.

Typical part price ranges (parts only)

These are common ranges for gas furnaces like the N9MPD075F12A2; confirm the exact part and current price in the parts list.

  • Flame sensor: $20 to $60
  • Hot surface igniter: $40 to $150
  • Limit switch: $20 to $80
  • Inducer motor assembly: $150 to $450
  • Blower motor: $200 to $700
  • Control board: $150 to $500
Example part on this model What it does Cost driver
Furnace burner flame sensor 1172827 Proves flame for safe burner operation Usually low parts cost
Icp furnace inducer vent motor assembly 1172823 Moves combustion air and vents exhaust Assembly cost, labor time
Icp furnace electronic control board 1172550 Manages ignition and safety timing Higher parts cost, diagnosis

Labor and service charges (what changes the total)

  • Diagnostic fee is common before parts are replaced
  • Simple swaps (sensor, switch) take less time
  • Motors and control boards take longer due to wiring and setup
  • After repair, techs verify safe ignition and venting operation

Safety and why it matters

This furnace includes safety devices that shut the system down during unsafe conditions. We follow the shutdown steps and warnings in the installation guide, especially for any work involving gas supply, electrical power, or combustion components.

How to keep costs down

  • Match the model number exactly: N9MPD075F12A2
  • Confirm the symptom before ordering (no heat, no ignition, blower not running)
  • Check basics first: filter, door switch, loose wiring
  • Order the exact replacement listed for your furnace, then compare photos and connectors

You can order parts from the list for this model, or search by model number on Sears PartsDirect.

Last updated: February 2026

Symptoms for treadmills

Choose a symptom to see related treadmill repairs.

Main causes: no power, bad power cord, tripped or faulty overload switch, bad power switch, wiring failure, bad motor co…

Main causes: damaged walking belt, improper belt tension, bad roller bearing…

Main causes: faulty sensors, wiring failure, bad control console…

Main causes: damaged walking belt, improper belt tension, lack of belt lubricant, bad drive motor…

Main causes: bad control console, wiring failure, bad motor control board…

Main causes: rear roller out of alignment, damaged walking belt, bad roller…

Main causes: missing safety key, bad control console, wiring failure, faulty motor control board, bad drive motor…

Repair guides for treadmills

These step-by-step repair guides will help you safely fix what’s broken on your treadmill.

How to replace a treadmill walking belt

How to replace a treadmill walking belt

A worn walking belt will begin to slow down during use. If your treadmill walking belt is worn out, replace it using the…

Repair time and Difficulty

 45 minutes or less
How to replace a treadmill walking board

How to replace a treadmill walking board

A worn-out walking board creates friction with the walking belt and causes the belt to slow down during use. Replace the…

Repair time and Difficulty

 30 minutes or less
How to replace a treadmill drive motor

How to replace a treadmill drive motor

A defective drive motor won't run when activated by the motor controller. Replace the treadmill drive motor if it doesn'…

Repair time and Difficulty

 15 minutes or less

Effective articles & videos to help repair your furnaces

Use the advice and tips in these articles and videos to get the most out of your treadmill.

How to get your furnace ready for winter

How to get your furnace ready for winter

Get expert tips for preparing your furnace for winter. Follow maintenance tips to keep your furnace in top shape.…

2023 HVAC regulation changes and how they may affect you

2023 HVAC regulation changes and how they may affect you

Find out how new DOE standards going into effect in 2023 can affect you and what you need to do.…

Top questions about Sears and Sears PartsDirect

Top questions about Sears and Sears PartsDirect

Get answers to frequently asked questions about Sears and Sears PartsDirect.…

Parts & More

Parts