Quasar room air conditioners enhance comfort in small spaces. Many owners rely on them due to their powerful compressors and evaporators that keep rooms at just the right temperature. Sears PartsDirect carries the Quasar air conditioner parts you need to keep the unit running smoothly.

Frequently bought Quasar parts

Panasonic Gasket CWB811008

Gasket

Part #CWH7070603U

Replaced by #CWB811008

Info Icon
Manufacturer substitution
This part replaces CWH7070603U. Substitute parts can look different from the original.
This item is not returnable
In Stock
$4.49
Minus Item
Qty
Plus Item
Quasar Vane CWL00047

Quasar Vane

Part #CWL00047
This item is not returnable
In Stock
$4.49
Minus Item
Qty
Plus Item
Quasar Nut CWL00016

Quasar Nut

Part #CWL00016
This item is not returnable
In Stock
$3.49
Minus Item
Qty
Plus Item

Popular maintenance items for Room Air Conditioners

Appliance Silicone Sealant WP279368

Appliance Silicone Sealant

In Stock
$52.18
10% OFF Phone Price : $58.18Info Icon
Minus Item
Qty
Plus Item
Dryer Screw WP3387230

Dryer Screw

Part #WP3387230
This item is not returnable
In Stock
$5.23
16% OFF Phone Price : $6.23Info Icon
Minus Item
Qty
Plus Item
Refrigerator Service Valve WP978025

Refrigerator Service Valve

In Stock
$41.18
13% OFF Phone Price : $47.18Info Icon
Minus Item
Qty
Plus Item
Refrigerator Defrost Timer WR9X502

Refrigerator Defrost Timer

In Stock
$90.01
6% OFF Phone Price : $96.01Info Icon
Minus Item
Qty
Plus Item
Dryer Washer W11236646

Dryer Washer

Part #W11236646
This item is not returnable
In Stock
$19.29
9% OFF Phone Price : $21.29Info Icon
Minus Item
Qty
Plus Item
Washer Fill Hose Washer, 4-pack 285448A

Washer Fill Hose Washer, 4-pack

Part #285448A
This item is not returnable
In Stock
$5.56
15% OFF Phone Price : $6.56Info Icon
Minus Item
Qty
Plus Item

Most common Quasar air conditioner parts that need replacing

  1. User interface control board. The user interface control board is a circuit board with selection buttons and display components, which is mounted on the control panel of the air conditioner. The user interface control board sends signals to the electronic control board to communicate the window air conditioner’s settings.
  2. Thermistor. The thermistor is a temperature sensor in the window air conditioner that sends information to the electronic control board.
  3. Compressor. The compressor receives low-pressure refrigerant gas from the evaporator and rotates to compress that refrigerant to a high-pressure gas that moves through the condenser. The refrigerant gets hot when compressed by the compressor pump. The condenser is a heat exchanger that removes heat from the refrigerant gas and condenses it into a high-pressure liquid refrigerant. The high-pressure liquid refrigerant flows through the expansion device and into the evaporator that's at low pressure. The high-pressure refrigerant expands and evaporates. It absorbs the latent heat of vaporization as it changes from a liquid to a gas, which causes the cooling action in the evaporator. The refrigerant flows through the evaporator and back to the compressor where the cycles starts over.
  4. Evaporator fan. The evaporator fan is mounted behind the evaporator assembly. It moves air across the evaporator fins and into the room for cooling.
  5. Electronic control board. The electronic control board controls the major electro-mechanical components in the window air conditioner. The electronic control board receives input from temperature sensors to monitor the temperatures inside the room and at the evaporator. With this information, the electronic control board manages the on/off cycling of the compressor to cool the room to the set temperature. The electronic control board activates the compressor and fans when it senses that the room temperature exceeds the set temperature.
  6. Condenser fan. The condenser fan moves air across the condenser to enhance the cooling process of the hot, compressed refrigerant that flows through the condenser.

How to fix your Quasar room air conditioner when water leaks inside your house

If water is leaking into the room from the air conditioner, adjust the air conditioner so the back of the unit is slightly lower than the front, to allow the condensate water to drain outdoors. Level the air conditioner according to the guidelines in the installation manual.

The air conditioner can also leak into the room if gaps around the window let warm, moist into the room, where it can condense on the front of the air conditioner. Seal air leaks in the cabinet or around the window opening.