  • Washer-met for Gibson GAC086Y7A2 - Part 309112501

    Compressor parts diagram

    Washer

    Part #5303002664

    Replaced by #309112501

    Info Icon
    Manufacturer substitution
    This part replaces 5303002664. Substitute parts can look different from the original.
    In Stock
    $25.44
    Minus Item
    Qty
    Plus Item
  • Room Air Conditioner Compressor Start Relay Kit for Gibson GAC086Y7A2 - Part 5304413630

    Compressor parts diagram

    Startr Kit

    Part #5303201723

    Replaced by #5304413630

    Info Icon
    Manufacturer substitution
    This part replaces 5303201723. Substitute parts can look different from the original.
    In Stock
    $212.58
    Minus Item
    Qty
    Plus Item
  • Foam Strip for Gibson GAC086Y7A2 - Part 5304407729

    Window mounting parts diagram

    Gasket

    Part #3002603

    Replaced by #5304407729

    Info Icon
    Manufacturer substitution
    This part replaces 3002603. Substitute parts can look different from the original.
    In Stock
    $50.62
    Minus Item
    Qty
    Plus Item
  • Condenser for Gibson GAC086Y7A2 - Part 309645401

    Compressor parts diagram

    Condenser

    Part #5303303195

    Replaced by #309645401

    Info Icon
    Manufacturer substitution
    This part replaces 5303303195. Substitute parts can look different from the original.
    In Stock
    $192.96
    Minus Item
    Qty
    Plus Item
  • Wrapper for Gibson GAC086Y7A2 - Part 5304417321

    Cabinet front and wrapper diagram

    Wrapper

    Part #5303302856

    Replaced by #5304417321

    Info Icon
    Manufacturer substitution
    This part replaces 5303302856. Substitute parts can look different from the original.
    In Stock
    $96.81
    Minus Item
    Qty
    Plus Item
  • Washer Screw for Gibson GAC086Y7A2 - Part 134178901

    Screw

    Part #5303303691

    Replaced by #134178901

    Info Icon
    Manufacturer substitution
    This part replaces 5303303691. Substitute parts can look different from the original.
    In Stock
    $43.07
    Minus Item
    Qty
    Plus Item
  • Complete Bulkhead for Gibson GAC086Y7A2 - Part 309602404

    Bulkhead

    Part #309602401

    Replaced by #309602404

    Info Icon
    Manufacturer substitution
    This part replaces 309602401. Substitute parts can look different from the original.
    In Stock
    $55.79
    Minus Item
    Qty
    Plus Item
  • Sgroud for Gibson GAC086Y7A2 - Part 5303270041

    Air handling parts diagram

    Sgroud

    Part #5303270041

    The manufacturer no longer makes this part, and there's no substitute part

  • Rail for Gibson GAC086Y7A2 - Part 5303302857

    Window mounting parts diagram

    Rail

    Part #5303302857

    The manufacturer no longer makes this part, and there's no substitute part

  • Fan Motor for Gibson GAC086Y7A2 - Part 309615702

    Air handling parts diagram

    Fan Motor

    Part #309615702

    The manufacturer no longer makes this part, and there's no substitute part

Most common symptoms to help you fix your room air conditioners

Main causes: clogged condensate drain, air conditioner not leveled properly, leaky window air seals …

Main causes: bad compressor, lack of refrigerant, bad compressor start relay, electronic control board failure…

Main causes: lack of electrical power, bad electronic control board, wiring failure, bad temperature sensor…

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Main causes: turning the air conditioner off and the back on too quickly, dirty or restricted condenser coil, compressor…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: dirty air filter, air conditioner is too small for the room, temperature set too cold, control failure…

Main causes: clogged drain hole, air conditioner not leveled properly…

Effective articles & videos to help repair your room air conditioners

Tapping into a new feature in the Search Bar on Sears PartsDirect

Tapping into a new feature in the Search Bar on Sears PartsDirect

Learn about a new feature added to the Search Bar on Sears PartsDirect…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Compact Stereo System
Compact Vhs-C Camcorder
Lawn & Garden Engine
Office Equipment
Speaker
Television
Trash Compactor
Vhs Players & Vcrs