Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Soleus Air SG-PAC-08E3 portable air conditioner

Soleus Air SG-PAC-08E3 portable air conditioner Parts

Here are the diagrams and repair parts for Soleus Air SG-PAC-08E3 portable air conditioner, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for SG-PAC-08E3 Portable Air Conditioner

  • Room Air Conditioner Touchpad for Soleus Air SG-PAC-08E3 - Part P-KY80-01

    Cabinet parts diagram

    Room Air Conditioner Touchpad

    Part #P-KY80-01

    The manufacturer no longer makes this part, and there's no substitute part

  • Water Box for Soleus Air SG-PAC-08E3 - Part P-KY80-13

    Cabinet parts diagram

    Water Box

    Part #P-KY80-13

    The manufacturer no longer makes this part, and there's no substitute part

  • Electronic Box for Soleus Air SG-PAC-08E3 - Part P-KY80-22

    Cabinet parts diagram

    Electronic Box

    Part #P-KY80-22

    The manufacturer no longer makes this part, and there's no substitute part

  • Room Air Conditioner Remote Control for Soleus Air SG-PAC-08E3 - Part P-KY80-36

    Cabinet parts diagram

    Room Air Conditioner Remote Control

    Part #P-KY80-36

    The manufacturer no longer makes this part, and there's no substitute part

  • Soleus Air Room Air Conditioner Window Exhaust Panel for Soleus Air SG-PAC-08E3 - Part P-KY80-42

    Cabinet parts diagram

    Soleus Air Room Air Conditioner Window Exhaust Panel

    Part #P-KY80-42

    The manufacturer no longer makes this part, and there's no substitute part

  • Water Switch for Soleus Air SG-PAC-08E3 - Part P-KY80-12

    Cabinet parts diagram

    Water Switch

    Part #P-KY80-12

    The manufacturer no longer makes this part, and there's no substitute part

  • Plate for Soleus Air SG-PAC-08E3 - Part P-KY80-19

    Cabinet parts diagram

    Plate

    Part #P-KY80-19

    The manufacturer no longer makes this part, and there's no substitute part

  • Evaporator for Soleus Air SG-PAC-08E3 - Part P-KY80-16

    Cabinet parts diagram

    Evaporator

    Part #P-KY80-16

    The manufacturer no longer makes this part, and there's no substitute part

  • Capillary for Soleus Air SG-PAC-08E3 - Part P-KY80-15

    Cabinet parts diagram

    Capillary

    Part #P-KY80-15

    The manufacturer no longer makes this part, and there's no substitute part

  • Room Air Conditioner Air Filter for Soleus Air SG-PAC-08E3 - Part P-KY80-20

    Cabinet parts diagram

    Room Air Conditioner Air Filter

    Part #P-KY80-20

    The manufacturer no longer makes this part, and there's no substitute part

Soleus Air Portable Air Conditioner SG-PAC-08E3 FAQs

For the Soleus SG-PAC-08E3 portable room air conditioner, unclogging the drain is usually a simple cleanout of the drain port, drain hose, and drain plug so collected water can flow freely into a pan. Always turn the unit off and unplug it before you start (see the draining steps in the owner's manual).

Safe, effective unclog steps (SG-PAC-08E3)

  1. Power down: Turn the unit off and unplug the power cord.
  2. Access the drain area: Locate the drain port and drain cap on the unit.
  3. Remove the drain cap: Take off the pre-installed drain cap.
  4. Check for blockage: Look for sludge, lint, or debris at the drain port opening.
  5. Clear the port:
    • Wipe the opening with a cloth.
    • Use a flexible plastic zip tie or small bottle brush to loosen buildup (avoid sharp tools).
  6. Flush the drain path: Slowly pour a small amount of warm water into the drain port to confirm it flows out.
  7. Set up the drain hose correctly (recommended for draining the tank): Attach the drain hose to the drain port using the drain hose clip, route it through the clamp, and keep the drain plug installed until you are ready to drain.

What to avoid

  • Do not run the unit while you are working on the drain.
  • Do not force metal objects into the drain port; it can damage internal plastic parts.
  • Do not tip the unit excessively; keep it upright as much as possible.

Quick troubleshooting checklist

  • Bucket full icon/alarm: The internal tank is full; drain it using the drain hose and drain plug method.
  • Slow draining: Recheck the drain plug for debris and confirm the hose is not kinked.
  • Recurring clogs: Clean the air filter regularly; restricted airflow can increase moisture retention and lead to more frequent draining needs.

Drain components and what they do

Component What it does Common issue
Drain port Outlet from the internal tank Sludge/debris at opening
Drain hose Routes water to a pan Kinked or pinched hose
Drain plug Seals the hose end until draining Debris preventing a tight seal
Clamp and drain hose clip Secures hose routing and connection Loose connection causing leaks

Why it matters

A clear drain path prevents the compressor from shutting off due to a full internal tank and helps your portable AC maintain cooling and dehumidifying performance during high humidity.

Last updated: February 2026

If your Soleus SG-PAC-08E3 portable air conditioner is running but not cooling, the most common causes are restricted airflow (blocked front intake or a dirty air filter), an incorrect temperature setting, or the unit going into a defrost cycle because the evaporator is frozen. Use the owner's manual troubleshooting steps to restore normal cooling.

Quick checks that fix most “no cooling” complaints

  • Make sure the unit is in cooling mode, not fan-only.
  • Lower the thermostat setting several degrees below room temperature.
  • Confirm nothing blocks the front of the unit (curtains, blinds, furniture).
  • Clean the air filter; a dirty filter restricts airflow and reduces cooling.
  • Close doors and windows; reduce heat sources in the room.
  • Check that cold air is not escaping into another area (open registers, returns, or gaps).

If the evaporator is frozen

A frozen evaporator can make the unit blow little or no cold air. The SG-PAC-08E3 can pause cooling while it defrosts, then resume automatically.

  • Turn the unit off and let it thaw.
  • Clean the air filter and clear airflow restrictions.
  • Restart cooling and allow time for the room to pull down in temperature.

What to expect (normal vs. problem)

Symptom Likely cause What we recommend
Fan runs, weak airflow Dirty filter or blocked intake Clean filter; clear obstructions
Runs but room stays warm Setpoint too high or room heat load Lower set temp; close doors/windows
Cooling stops, then returns Defrost cycle from frozen evaporator Wait for defrost; improve airflow
Cooling delayed after restart Compressor protection delay Wait about 3 minutes

Why it matters

Portable AC units depend on steady airflow across the evaporator coil. When airflow is restricted, the coil can get too cold, freeze up, and cooling performance drops sharply even though the fan and compressor may still be running.

Last updated: February 2026

A 0.8 ton AC is typically sized for a small room, about 100 to 150 sq. ft. For the Soleus SG-PAC-08E3 specifically, the manual lists it as an 8,000 BTU portable air conditioner, which fits that same small-room range in most homes (depending on heat, sun, and insulation). See the owner's manual for the model’s rated specs and operating guidance.

Quick sizing guide (0.8 ton class)

Use these as practical targets when choosing a room size for an 8,000 BTU portable unit like the Soleus SG-PAC-08E3:

  • 100 to 150 sq. ft.: best fit for typical bedrooms, offices, and small dens
  • 150 to 200 sq. ft.: works only if the room is shaded, well-insulated, and doors stay closed
  • Over 200 sq. ft.: expect longer run times and weaker comfort, especially in heat waves
  • High ceilings (over 8 ft.): treat the room as “larger” than its floor area
  • Strong sun exposure: treat the room as “larger” than its floor area

What changes the “right” room size

Even with the same BTU rating, real-world performance depends on the load in the space.

  • Sunlight (south or west facing windows)
  • Insulation and air leaks (drafty doors, old windows)
  • Ceiling height and open floor plans
  • Heat sources (computers, TVs, cooking nearby)
  • People (more occupants add heat and humidity)

BTU and room size at a glance

Cooling capacity Common “ton” label Typical room size
8,000 BTU ~0.67 ton ~100 to 150 sq. ft.
10,000 BTU ~0.83 ton ~150 to 250 sq. ft.

Why it matters

If the room is too large, the compressor runs longer, comfort drops, and humidity control can suffer. If the room is appropriately sized, you get steadier temperatures, better moisture removal, and more efficient operation.

Last updated: February 2026

To find the right AC parts, we match parts to your exact air conditioner model number. For your Soleus SG-PAC-08E3 portable room air conditioner, start with the model and serial label (typically on the back of the unit) and confirm the correct configuration in the owner's manual.

Step-by-step: how we recommend finding the correct part

  • Locate the model number and serial number on the unit label (the manual notes the serial number is on the back of the unit).
  • Confirm the unit type and key accessories: portable AC with exhaust hose and window kit.
  • Identify the system you are repairing (airflow, drainage, electrical, or installation).
  • Use the model number SG-PAC-08E3 to search the parts list for compatible replacement parts.
  • Compare the part description to what you see on the unit (shape, mounting points, connectors).
  • If the issue is electrical (won’t power on, trips), stop and follow the safety guidance in the manual before testing.

What to check first (common “parts” people mean on this model)

This model uses a window kit and exhaust hose when running in cooling or dehumidifier mode. These items are often what customers need to replace or re-fit.

What you need Where it’s used Quick fit check
Exhaust hose Vents hot air out Ends screw onto adapters; avoid kinks for best efficiency
Window slider kit Seals the window opening Must span your window width and hold the hose adapter
Power cord (LCDI) Power and safety trip protection Must reset manually after a trip; do not use extension cords
Air inlet/outlet grilles Airflow path Must stay unblocked; keep clearance around the unit

Why it matters

Portable AC parts are model-specific because hose adapters, window sliders, and electrical components must match the exact design. Using the correct SG-PAC-08E3 parts helps prevent poor cooling, air leaks, and nuisance power trips.

Last updated: February 2026

To reset your Soleus SG-PAC-08E3 portable air conditioner, use the TEST and RESET buttons on the LCDI plug (the safety plug on the power cord). Plug it in, press TEST to trip power, then press RESET to restore power; then restart the unit.

Reset steps (LCDI plug)

  • Turn the air conditioner OFF.
  • Plug the power cord into a wall outlet.
  • Press TEST on the plug; power should cut off.
  • Press RESET on the plug to restore power.
  • Turn the unit back ON and select your mode (Cool, Fan, or Dry).

If it still will not run after resetting

The SG-PAC-08E3 has a protective compressor time delay, so cooling may not start for about 3 minutes after power is restored or the unit is turned back on.

  • Wait 3 minutes, then try starting cooling again.
  • Check your home breaker/fuse and reset/replace if needed.
  • Make sure the cord is fully seated in the outlet.
  • If the RESET button will not stay engaged, discontinue use and have the unit checked by a qualified service technician.

What the TEST/RESET buttons are (and why it matters)

The LCDI plug is designed to cut power if it detects electrical leakage in the cord. Using the reset correctly helps restore safe operation and prevents nuisance shutdowns.

Button What it does What you should see
TEST Trips the safety circuit Unit loses power
RESET Restores power to the unit Unit can be turned on

Reference

For the exact wording, safety notes, and operating details for this model, use the SG-PAC-08E3 owner's manual.

Last updated: February 2026

Most common symptoms to help you fix your room air conditioners

Main causes: clogged condensate drain, air conditioner not leveled properly, leaky window air seals …

Main causes: bad compressor, lack of refrigerant, bad compressor start relay, electronic control board failure…

Main causes: lack of electrical power, bad electronic control board, wiring failure, bad temperature sensor…

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Main causes: turning the air conditioner off and the back on too quickly, dirty or restricted condenser coil, compressor…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: dirty air filter, air conditioner is too small for the room, temperature set too cold, control failure…

Main causes: clogged drain hole, air conditioner not leveled properly…

Effective articles & videos to help repair your room air conditioners

Tapping into a new feature in the Search Bar on Sears PartsDirect

Tapping into a new feature in the Search Bar on Sears PartsDirect

Learn about a new feature added to the Search Bar on Sears PartsDirect…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Boiler
Bottom-Mount Refrigerator
Built-In Microwave
Chainsaw
Dishwasher
Dryer
Line Trimmer
Others
Parts
Pressure Washer
Range
Refrigerator
Side-By-Side Refrigerator
Snowblower
Vacuum Cleaner
Walk-Behind Mower