Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number
Amana RC24085C2DR REV B room air conditioner

Amana RC24085C2DR REV B room air conditioner Parts

Here are the diagrams and repair parts for Amana RC24085C2DR REV B room air conditioner, as well as links to manuals and error code tables, if available.

By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for RC24085C2DR REV B Room Air Conditioner

  • Control Knob for Amana RC24085C2DR REV B - Part WPBT3075631

    Outercase/curtains/front assembly diagram

    Control Knob

    Part #BT3075631

    Replaced by #WPBT3075631

    Info Icon
    Manufacturer substitution
    This part replaces BT3075631. Substitute parts can look different from the original.
    In Stock
    $56.59
    Minus Item
    Qty
    Plus Item
  • Thermostat for Amana RC24085C2DR REV B - Part BT1370801

    Controls (no image available) diagram

    Temperature Control

    Part #BT1370801

    Replaced by #BT1370801

    Info Icon
    Manufacturer substitution
    This part replaces BT1370801. Substitute parts can look different from the original.
    In Stock
    $102.50
    Minus Item
    Qty
    Plus Item
  • Evaporator Coil for Amana RC24085C2DR REV B - Part 3064606

    Evaporator (no image available) diagram

    Evaporator Coil

    Part #3064606

    The manufacturer no longer makes this part, and there's no substitute part

  • Compressor for Amana RC24085C2DR REV B - Part BT9266205

    Evaporator (no image available) diagram

    Compressor

    Part #BT9266205

    The manufacturer no longer makes this part, and there's no substitute part

  • Left Vent Assembly for Amana RC24085C2DR REV B - Part BT3075413

    Outercase/curtains/front assembly diagram

    Left Vent Assembly

    Part #BT3075413

    The manufacturer no longer makes this part, and there's no substitute part

  • Bolt - Comp for Amana RC24085C2DR REV B - Part BT1393704

    Evaporator (no image available) diagram

    Bolt - Comp

    Part #BT1393704

    The manufacturer no longer makes this part, and there's no substitute part

  • Suction Line Assembly (rc18090c2l, Rc18090c2l Rev A, Rc18090c2lr, Rc18090c2lr Rev A) for Amana RC24085C2DR REV B - Part 3093647

    Evaporator (no image available) diagram

    Suction Line Assembly (rc18090c2l, Rc18090c2l Rev A, Rc18090c2lr, Rc18090c2lr Rev A)

    Part #3093647

    The manufacturer no longer makes this part, and there's no substitute part

  • Liquid Line Assembly for Amana RC24085C2DR REV B - Part 3093836

    Evaporator (no image available) diagram

    Liquid Line Assembly

    Part #3093836

    The manufacturer no longer makes this part, and there's no substitute part

  • Front Frame for Amana RC24085C2DR REV B - Part BT3075102

    Outercase/curtains/front assembly diagram

    Front Frame

    Part #BT3075102

    The manufacturer no longer makes this part, and there's no substitute part

  • Discharge Line (rc24085c2d, Rc24085c25 Rev A, Rc24085c2d Rev B, Rc24085c2dr) for Amana RC24085C2DR REV B - Part 3093690

    Evaporator (no image available) diagram

    Discharge Line (rc24085c2d, Rc24085c25 Rev A, Rc24085c2d Rev B, Rc24085c2dr)

    Part #3093690

    The manufacturer no longer makes this part, and there's no substitute part

Most common symptoms to help you fix your room air conditioners

Main causes: clogged condensate drain, air conditioner not leveled properly, leaky window air seals …

Main causes: bad compressor, lack of refrigerant, bad compressor start relay, electronic control board failure…

Main causes: lack of electrical power, bad electronic control board, wiring failure, bad temperature sensor…

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor…

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor…

Main causes: turning the air conditioner off and the back on too quickly, dirty or restricted condenser coil, compressor…

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure.…

Main causes: dirty air filter, air conditioner is too small for the room, temperature set too cold, control failure…

Main causes: clogged drain hole, air conditioner not leveled properly…

Effective articles & videos to help repair your room air conditioners

Tapping into a new feature in the Search Bar on Sears PartsDirect

Tapping into a new feature in the Search Bar on Sears PartsDirect

Learn about a new feature added to the Search Bar on Sears PartsDirect…

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown…

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers.…

Parts & More

Camcorder
Compact Stereo System
Cycling
Dvd Player
Heating & Cooling
Heating & Cooling Combined Unit
Line Trimmer
Plumbing
Sports & Leisure
Television
Upright Freezer
Vhs Players & Vcrs