Get free shipping on your order, with any water filter subscription. Find my filter

Open Hamburger Menu
Sears Parts Direct
Tips to find your model number

Gibson AK18E7RVA room air conditioner - lg34089160 Parts

Here are the diagrams and repair parts for Gibson AK18E7RVA room air conditioner - lg34089160, as well as links to manuals and error code tables, if available.

Gibson AK18E7RVA room air conditioner - lg34089160
By Schematic
SELECT DIAGRAM
?

This is the number corresponding to the part on the diagram / schematic

Browse Parts for AK18E7RVA Room Air Conditioner - LG34089160

  • Universal/multiflex (frigidaire) Cover for Gibson AK18E7RVA - Part 5303002067

    System parts diagram

    Cover

    Part #3002067

    Replaced by #5303002067

    Info Icon
    Manufacturer substitution
    This part replaces 3002067. Substitute parts can look different from the original.
    In Stock
    $42.36
    Minus Item
    Qty
    Plus Item
  • Room Air Conditioner Fan Motor for Gibson AK18E7RVA - Part 309630604

    Air handling parts diagram

    Motor

    Part #3015293

    Replaced by #309630604

    Info Icon
    Manufacturer substitution
    This part replaces 3015293. Substitute parts can look different from the original.
    In Stock
    $459.83
    $12.00 OFF Phone Price : $471.83Info Icon
    Minus Item
    Qty
    Plus Item
  • Link, Rh for Gibson AK18E7RVA - Part 5303002162

    Cabinet parts diagram

    Link

    Part #3002162

    Replaced by #5303002162

    Info Icon
    Manufacturer substitution
    This part replaces 3002162. Substitute parts can look different from the original.
    In Stock
    $38.52
    Minus Item
    Qty
    Plus Item
  • Service Cord for Gibson AK18E7RVA - Part 3002363

    Electrical parts diagram

    Service Cord

    Part #3002363

    The manufacturer no longer makes this part, and there's no substitute part

  • Link, Lh for Gibson AK18E7RVA - Part 5303002163

    Cabinet parts diagram

    Link

    Part #3002163

    Replaced by #5303002163

    Info Icon
    Manufacturer substitution
    This part replaces 3002163. Substitute parts can look different from the original.
    In Stock
    $32.97
    Minus Item
    Qty
    Plus Item
  • Room Air Conditioner Capillary Line for Gibson AK18E7RVA - Part 3203179

    #NI

    All parts diagram

    Capillary Tube

    Part #3001746

    Replaced by #3203179

    Info Icon
    Manufacturer substitution
    This part replaces 3001746. Substitute parts can look different from the original.
    In Stock
    $111.22
    Minus Item
    Qty
    Plus Item
  • Louver for Gibson AK18E7RVA - Part 5303002459

    Cabinet parts diagram

    Louver

    Part #3002459

    Replaced by #5303002459

    Info Icon
    Manufacturer substitution
    This part replaces 3002459. Substitute parts can look different from the original.
    In Stock
    $108.14
    Minus Item
    Qty
    Plus Item
  • Westinghouse Room Air Conditioner Filter Dryer for Gibson AK18E7RVA - Part 5300265301

    #NI

    All parts diagram

    Filter Drier

    Part #3017429

    Replaced by #5300265301

    Info Icon
    Manufacturer substitution
    This part replaces 3017429. Substitute parts can look different from the original.
    In Stock
    $290.45
    Minus Item
    Qty
    Plus Item
  • Control for Gibson AK18E7RVA - Part 5303002176

    Electrical parts diagram

    Control

    Part #3002176

    Replaced by #5303002176

    Info Icon
    Manufacturer substitution
    This part replaces 3002176. Substitute parts can look different from the original.
    In Stock
    $318.66
    Minus Item
    Qty
    Plus Item
  • Washer-met for Gibson AK18E7RVA - Part 309112501

    System parts diagram

    Washer

    Part #3002664

    Replaced by #309112501

    Info Icon
    Manufacturer substitution
    This part replaces 3002664. Substitute parts can look different from the original.
    In Stock
    $25.44
    Minus Item
    Qty
    Plus Item

Most common symptoms to help you fix your room air conditioners

Main causes: clogged condensate drain, air conditioner not leveled properly, leaky window air seals ...

Main causes: bad compressor, lack of refrigerant, bad compressor start relay, electronic control board failure...

Main causes: lack of electrical power, bad electronic control board, wiring failure, bad temperature sensor...

Thermostat problems, bad compressor/condenser fan capacitor, lack of refrigerant, failed compressor...

Dirty air filter, clogged condenser coils, low refrigerant charge, faulty compressor...

Main causes: turning the air conditioner off and the back on too quickly, dirty or restricted condenser coil, compressor...

Main causes: errant thermostat settings, lack of electrical power, clogged drain line, wiring failure, control failure....

Main causes: dirty air filter, air conditioner is too small for the room, temperature set too cold, control failure...

Main causes: clogged drain hole, air conditioner not leveled properly...

Effective articles & videos to help repair your room air conditioners

Tapping into a new feature in the Search Bar on Sears PartsDirect

Tapping into a new feature in the Search Bar on Sears PartsDirect

Learn about a new feature added to the Search Bar on Sears PartsDirect...

How to tell if a fuse is blown

How to tell if a fuse is blown

Learn how to tell whether a fuse is blown...

Keeping your smart appliances secure from hackers

Keeping your smart appliances secure from hackers

Find out how to protect your smart appliances from malevolent invasions by hackers....

Parts & More

Bottom-Mount Refrigerator
Central Air Conditioner
Dishwasher
Electric Range
Home Improvement
Range/Microwave Combo
Side-By-Side Refrigerator
Top-Mount Refrigerator
Washer