Model #R-2100 Goldstar air conditioner -room

  • Cabinet Parts
    3 Results
  • Wiring Diagram
    3 Results

Question and Answers

Q:

electrolux 2100 keeps shutting down

A:

Thank you for your question.

I can understand your frustration when the vacuum keeps turning off.

• Check to see if the C bag is installed correctly and making contact with the switch next to the bag card board.

• There is a full bag switch that needs to be pushed in to keep the unit from shutting off. I noticed that you did not say that the full bag light is not coming on.

• You are saying that the protection light is coming on and then it shuts down for about a minute and then it comes back on.

• You may have to take the vacuum to a vacuum repair shop to have the vacuum valve control replaced. There are some small hoses and sensors that may be indicating to the control that there is an air restriction and it shuts down to protect the motor from overheating. If the vacuum is not running hot, the protection circuit is not working correctly.

I hope this will help with your vacuum problem.

Thank you for using Manage My Life.

Read More
Sam A -
Sears Technician
November 09, 2010
Q:

how do I R & R this part touchpad #97013466

A:

There is not a procedure available for the replacement of the touchpad on that older Kenmore range hood. These general tips may help you complete that repair:

Shut off the house circuit breaker to disconnect electrical power and remove the filter on the side that has that touchpad. You may be able to disconnect that wires and pull that touchpad out after removing that filter. If not, then you may need to remove the blower motor and/or other components. The owner's manual/installation guide will normally provide directions for removing the blower motor. You may need to pull the range hood down to access that touchpad. You can view the parts image for the blower on this page: Kenmore Range Hood Model 233.5548910 Parts . The parts diagram may help you access and replace that part.

If you get to the point where you need to have a service technician replace that touchpad, you can schedule service through this link: Sears Home Services .

Read More
Lyle W -
Sears Technician
January 15, 2013
A:

Here is the image.

Read More
Lyle W -
Sears Technician
January 15, 2013
See more answers
Q:

Gas Footvalve R&R JGP330EP2BG

A:

Thank you for your question and I understand your concern.

Yes, the glass top must be taken off to access the burner valve. I added an image below with the procedure of removing the glass top. NOTE: Turn the gas supply off and disconnect the power cord from the power source before servicing.

 I hope this is helpful. If I may be of further assistance as more details become available, please reply to this post. 

Read More
Joey S -
Sears Technician
September 11, 2013