Model #NW108-2B Arrow building

  • Replacement Parts
    3 Results

Question and Answers

Q:

Have Maytag dryerLDG-482won't stay lit. Cleaned everything no lint anywhere. It ignites 2/3 times and goes out .Will try to ignite but won't.Seems 2B a sensor?

A:

If you find the glow bar ignitor glowing red for a few seconds and then fade off without any burner ignition, replace the coils on the gas valve assembly. Without knowing the serial number of your dryer I will not be able to provide a specific part number for the coils. The first two digits of the serial number dictates what the series number is.

You can look up parts at Sears Parts Direct .

Read More
Joey S -
Sears Technician
July 09, 2010
Q:

How to clean continuous cleaning ovens?

A:

If the continuous clean feature is still working you should use a dishwashing detergent such as Joy or Palmolive on a wet cloth or a plastic scrubber.

If the continuous feature is no longer working you can use regular oven cleaner such as Easy Off. If you don't care for the continuous clean feature, clean it like you would any oven.

Read More
Jimmy K -
Sears Technician
August 05, 2008
Q:

1997 Craftsman 1/2 HP Belt Drive Garage Door Logic Board Compatibility

A:

Thank you for your question on the logic board replacement.

If the part number for your model of garage door opener is as you listed the ending numbers are just engineering changes and it will work fine.

I hope this will help.

Sam A.

Read More
Sam A -
Sears Technician
November 14, 2011