Q:

Problem with burner

A:

Your details seem to indicate that the burner did not work properly ever since it was converted to LP gas. I recommend that you have the installer that converted the range examine that burner. The installer will probably need to check the installation and alignment of the orifice.

Read More
Lyle W -
Sears Technician
August 24, 2011
A:

I recommend that you check the burner and the cap. They should both be marked XL. If you have a mismatched set (cap and burner head) then this could be causing your problem. You should also have a choke installed in that right front burner as shown in the image below. Make sure that the choke is properly installed and is not interfering with the installation of that burner cap. These additional tips may help. Let us know if you need more assistance.

Read More
Lyle W -
Sears Technician
August 29, 2011