Model #KWX-5V Kenmore boiler-storage tanks

  • Jacket/base Parts
    3 Results
  • Natural Gas Burner/manifold Assy
    3 Results
  • Boiler Controls/piping
    3 Results

Question and Answers

Q:

Color orientation for 5V 0V Out on Kenmore Washing Machine Pressure Switch #134407800

A:

Thank you for your question and I understand your concern.

I added a wiring diagram in the image below. The blue wire will connect to C4.1, white to C4.3 and the red will connect to c4.4 and I hope this helps. The side of the connector with red wire should be nearest the black/red wire according to the wire diagram.

I hope this is helpful. If I may be of further assistance as more details become available, please reply to this post.

Read More
Joey S -
Sears Technician
March 06, 2012
Q:

Engine won't start- Doesn't turn over. 917.271814

A:

Thank you for your question.

 

I am sorry you are having this problem with the tractor. I recommend determining what is causing the engine not to turn over. First, make sure the engagement lever is down or the PTO button is pushed in and the brake pedal is fully depressed or the tractor will not attempt to turn over. If you have already done this, I recommend checking the fuse. The fuse is located behind the dash. If the fuse is good, you have a wiring or switch problem. The easiest way to pin point the problem is with a volt meter. If you do not have a meter, you can purchase one relatively cheap.

 

Turn the meter to check dc volts, and then hold the black lead to the black negative battery terminal for all of the voltage checks. Place the red lead on the positive terminal of the battery. The reading should be 12 volts. If you have a 12 volt reading, move the red lead to the first blue dot in the image. Your reading should be 12 volts. If you have 12 volts, have someone sit on the tractor and hold the brake pedal while turning the key for the rest of the checks. While they have the key turned to the start position, move the red lead to the next blue dot. The reading should always be 12 volts. Then move to the next blue dot. If you lose the 12 volts, the problem is between the last blue dot you had the voltage and where you lost the voltage. If you have 12 volts all the way to the white wire on the solenoid, the solenoid or the starter is defective.

 

To determine starter or solenoid short the two large posts on the solenoid together with a screwdriver. There should be a spark it is normal. Once shorted the starter should run. 

 

If the tractor still will not run once you get the starting issue fixed, please let me know. I will be happy to assist you with diagnosing that.

 

 

Thank you for using Manage my life.

 

Mark T.

Read More
Mark T -
Sears Technician
October 03, 2013
Q:

Color code of wire to Pressure Switch on Washing Machine

A:

Thank you for your question and I understand your concern.

I added a wiring diagram in the image below. The blue wire will connect to C4.1, white to C4.3 and the red will connect to c4.4 and I hope this helps. The side of the connector with red wire should be nearest the black/red wire according to the wire diagram.

I hope this is helpful. If I may be of further assistance as more details become available, please reply to this post.

Read More
Joey S -
Sears Technician
March 06, 2012