Q:

Why would my microwave work lights stop working after I replaced a bad 40 watt bulb with a 25 watt bulb?

A:

Putting in a 25 watt bulb would not cause any damage to the microwave. It sounds like something shorted when you were replacing the bulbs. Someone will need to check to see if you are getting 120 volts ac to the light sockets.

If you are not someone needs to trace the voltage back to the control board and see if it is passing the 120 volts out.

If you don't have a volt meter or are not comfortable making these tests, get a technician to make the tests for you.

There is no fuse in the light circuit to blow. There is only one fuse in the microwave. If it blows everything stops working.

Read More
Jimmy K -
Sears Technician
May 21, 2008