Q:

Craftsman compressor starts but wont stay running. 921166370 Craftsman Air compressor

A:

That type of problem is normally caused by a failed check valve (part E101208). Replacing that part will likely fix your problem.

 

If you need more help, reply with addtiional details and we will assist you further. 

Read More
Lyle W -
Sears Technician
November 08, 2013
Q:

Help removing the connecting rod from the crank craftsman 1hp 4 gal 125 psi 921166370 Craftsman Air compressor

A:

Thank you for your question.

I am sorry you are having a problem with the air compressor. To remove the connecting rod you may need a two-jaw puller. First, remove the head and cylinder. Then hook the jaws on the backside of the connecting rod and position the threaded part of the puller in the center of the crankshaft. While holding the jaws in position, tighten the bolt on the puller to pull the connecting rod off the shaft. Once it is removed, you can loosen the bolt in the crankshaft and remove it from the end of the motor shaft. After you get the unit apart, you can order the piston kit. The part number for the kit is E100251 and can be ordered from the following link. Piston kit for Craftsman air compressor model 921166370.   The kit comes with the piston, rings, connecting rod, and crankshaft. After you install the new parts be sure to add the recommend oil to the crankcase.

 

I hope this is helpful.  Please let me know if you need further assistance.   Thank you for using Manage my life. Mark T.  

Read More
Mark T -
Sears Technician
March 19, 2013
A:

Trey, The eccentric should slide off the shaft once the bolt is removed. The image below shows the bolt that needs to be removed. Just click on the image to enlarge it. Thank you for using Manage my life. Mark T.

Read More
Mark T -
Sears Technician
April 09, 2013