Question and Answers

Q:

I would like to find out what the power rating of a free standing range (the complete model number is #79092903010.) - exactly how much wattage it will consume

A:

The KW power rating of this range is shown in the image below. It normally requires a 40 amp breaker with 8 gauge copper wire size as shown below. This should be the specifications that you need for your remodel.

Read More
Lyle W -
Sears Technician
June 28, 2011
Q:

Kenmore range lamplight indicator is out.

A:

Thank you for your question and I understand your concern.

Based on your symptom and details, in order for every one of the surface ON indicators to fail at the same time I suspect the ON indicator lost the neutral supply (white wires) to the surface ON indicators.  You can likely find a loose or disconnected white wire (neutral wire) connecting to the terminal block or somewhere behind the control panel. You can slide the range out and disconnect the power cord from the power source.

After disconnecting the power cord, remove the screws from the cover behind the control panel. Remove the cover and make a visual inspection of all the white wires. It will likely be the white wire connected between the terminal block and where it connects in a series circuit to each of the surface ON indicator lights. 

 I hope this is helpful. If I may be of further assistance as more details become available, please reply to this post. 

 If you get to the point where you need to have a service technician diagnose and repair this failure, you can schedule service through this link:Sears Home Services.

Read More
Joey S -
Sears Technician
August 15, 2013