Q:

commercial dryer

A:

You could have weak gas valve coils. Since the burner initially ignites properly, the thermostat and radiant sensor are likely okay. If the igniter glows and then cycles off but the burner will not light after the initial burn then you will probably need to replace the gas valve coils.

This information may help you resolve your dryer heating failure.

If you need more assistance, reply with additional details and the full model number of your dryer.

Read More
Lyle W -
Sears Technician
July 15, 2011
Q:

commercial washer

A:

Thank you for your question and I understand your concern.

It is normal for the tub to fill half full with water in the rinse cycle. The washer is designed this way in order to meet the Department of Energy (DOE) requirements/standards.

Read More
Joey S -
Sears Technician
August 29, 2011
A:

Sally: Thanks for the model number. My previous answer still applies. The tub will only fill about half way full of water in the rinse cycles. This is normal. The washer must meet the Department of Energy standards.

Read More
Joey S -
Sears Technician
August 29, 2011
See more answers
Q:

Commercial coin dryer

A:

The procedure for lengthening the drying time on this type of dryer is shown in the image below.

Be sure that you unplug the dryer before accessing internal components.

Here is a link for the full owner's manual/installation guide on that dryer: Owner's Manual .

If you need more help, reply with additional details and we will assist you further.

Read More
Lyle W -
Sears Technician
May 30, 2011