Q:

I have a Kemore 580-54501801 Dehumidfier it ices up and does not accumulate water

A:

Low temperatures and low-humidity conditions can cause frost to appear on the evaporator coils. It works best in temperatures above 65 degrees and when the relative humidity is above 45%. If you have the fan speed on low then it may help to set the fan speed to high.

If the sealed refrigerant system is short on Freon it can also cause icing/frost to appear in a small section of the evaporator. Your dehumidifier has a five (5) year sealed system warranty if it fails. Sears will repair/replace the compressor, tubing and refrigerant if found defective in workmanship free of charge. Here is a link that will provide the nearest drop-off locations: Sears Home Services .

Read More
Joey S -
Sears Technician
July 22, 2010
Q:

What glue will work on a stress crack of a Kenmore Dehumidifie model 580-54501801. Is Styrene?

A:

Thank you for your question.

• You didn’t say which part you are talking about. But I would suggest if you are just trying to repair a crack in the plastic that you us a Gel-type of super glue.

• If this is the water container I would suggest ordering a replacement bucket because leakage could cause water damage to the surrounding area.

• If it is some other non-functional plastic part then touching up with super glue should work as a temporary fix. A long term repair would be to replace the part.

• You can order the part in question from Sears Parts Direct .

Note! Always use care when using this type of adhesive, use eye protection and observe safe handling practices. It will glue skin together.

I hope this will help.

Thank you for using Manage My Life.

Read More
Sam A -
Sears Technician
September 03, 2010
Q:

2 year old Kenmore Dehumidifer #58054501801: The empty bucket light would never shut off & stopped the unit from working, even after replacing the switch

A:

The control board that detects the position of that switch is KEY 4-A in that parts diagram on the Sears PartsDirect website. The part number for that control board is EBR36909302. (The control board 18-A that Aashe describes in the above post is for the control panel buttons.) The procedure for accessing that component is shown in the second image below. Be sure that you unplug the dehumidifier before accessing internal components. The wiring diagram for the unit is shown in the first image. You can check the continuity of the wiring in that bucket switch circuit using that information. This information should help you fix this problem. If you need more assistance, reply with additional details.

If you do not feel confident repairing this problem yourself, then you can have it repaired by a Sears technician. Here is a link that will provide the nearest drop-off locations: Sears Home Services .

Read More
Lyle W -
Sears Technician
July 21, 2011