Q:

We have a model 580.54501500 dehumidifier, it keeps running. It removes water. I set it to 70% and it keeps running. What should I do?

A:

The first thing to check is if the space you are trying to dehumidify is larger than the capacity of your dehumidifier. If you can close off part of the area for a test that would tell you. If the dehumidifier is rated to do what you are asking the humitity control on the unit may be defective.

If you program the control to 35% and press the down button on the control the dehumidifier will run continuously. When you raise the humidiy setting it disengages the continuous cycle.

Read More
Jimmy K -
Sears Technician
June 23, 2008
Q:

My Kenmore dehumidirier won't come on

A:

Thank you for your question.

I can understand you wondering why changing the location had this effect on the operation of the dehumidifier.

You have done a good job in diagnosis the unit. This error code of 01 indicates one of two possibilities. First it could be the Bucket Switch 6600A30003C. And if you feel comfortable with installing a jumper on the switch to check it, you will be able to tell if that is the problem. If you do that and the error code is still there it is the PCB Main 6871A10141B.

SAFETY NOTICE: Be sure to disconnect power to the appliance before performing any repairs. If you are not comfortable with doing any voltage checks that might be recommended, please contact your local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.

If you do not feel confident repairing this problem yourself, then you can have it repaired by aSears Technician.

Read More
Sam A -
Sears Technician