Question and Answers

Q:

refrigerator laid down during transit. left upright for 24 hrs without plugging in and told to plug in for 3 min unplug for 10 (5-6 times) correct info?

A:

The refrigerator should be left upright for 24 hours after being laid down for transit. After 24 hours you can plug the refrigerator in and leave it turned on.

When a refrigerator is laid down for transit, some of the oil will run out of the compressor into the evaporator and suction line. Twenty four hours is adequate time for the oil to run back into the compressor.

Read More
Jimmy K -
Sears Technician
July 09, 2010
Q:

what does code f 05 mean

A:

The "F05" fault code indicates a Water Temperature Sensor Error. If during the water heating step in the wash cycle, the water temperature sensor (NTC) value is out of range, the "F05" error code will be displayed. See image below for further instructions.

Potential Causes:

  1. Check the Water Temperature Sensor resistance. It should measure 9.7K ohms at 86 degrees.
  2. Check connections to the Water Temperature Sensor
You will likely find the wire connection had come loose from the temperature sensor. Without having the model number of your HE3t washer I will not be able to confirm if the heater and sensor is located at the lower backside of the tub or at the front lower section of the tub. Disconnect the power cord from the power source before removing the front lower access panel and checking for loose connections on the temperature sensor.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Read More
Joey S -
Sears Technician
August 04, 2010
Q:

Is 56" the width of the 56 X 84 Ricardo Ultimate Black Out Curtain?

A:

The 56 designates the width in inches. The 84 designates the height. For a window that is 84" wide, you should need just 2 of the panels. You should not need extra length for gathering on a black out curtain. You can also use the 114" wide by 84" long curtain for the 84" wide window.

Read More
Lyle W -
Sears Technician
February 17, 2010