Question and Answers

Q:

what to do? thermostat for freezer remain at 15 degrees and refrigerator at 12. recommended is 0 degrees and 32. Kenmore elite 10644433601

A:

If you have to set the controls to 15 degrees in the freezer and 12 degrees in the refrigerator to get normal temperatures inside, either the control board or the sensors have failed.

You should call 1-800-469-4663 or go to www.searshomeservices.com and schedule service for a Sears technician to diagnose and repair the problem.

Read More
Jimmy K -
Sears Technician
July 12, 2010
Q:

remington22lr model 66

A:

I see that Marc posted a link in the above response for the page on the Remington website that has the Owner's Manual links. That should help you find the manual for the Remington Model 66 rifle.

Read More
Lyle W -
Sears Technician
December 26, 2012
Q:

my ignitor has 66 omhs instead of 40 omhs is this a problem

A:

Thank you for your question.

I can understand wanting the information on the igniter.

Yes, I would change the igniter if the ohms are that far off. It needs to be real close to 40 ohms or it will not get hot enough satisfy the sensor and open the gas valves.

I hope this will help.

Thank you for using Manage My Life.

Read More
Sam A -
Sears Technician
December 10, 2010