Model #23358173600 Kenmore Elite range hood

  • Range Hood
    3 Results

Question and Answers

Q:

kenmore elite range hood 23358173600

A:

The wiring diagram for this range hood is shown in the image below. That information may help you diagnose and repair this failure. Be sure that you shut off the house circuit breaker for the range hood before accessing internal components. Your details indicate that you have already been checking live voltage from the transformer and the control. Use extreme caution when conducting those live voltage checks. I recommend that you wear proper safety equipment (insulated rubber electrical safety gloves and safety goggles). Disconnect electrical power as soon as voltage checks are completed .

For the lights, the essential voltage out of that transformer is the 10 VAC on the yellow wire. You should also detect low voltage AC going to the lights through that black wire. The neutral circuit through the lights needs to be complete through that white wire. I highlighted those wires on the wiring diagram below. If you have 10 VAC going into the control board on the yellow wire then your transformer should be okay. If you do not have that output voltage from the transformer then that component will probably need to be replaced.

You can order parts from the Sears PartsDirect website.

I hope that this information helps. If you need more assistance, reply with additional details.

If you get to a point where you need to have a service technician repair this failure, you can schedule one through this link: Sears Home Services .

Read More
Lyle W -
Sears Technician
December 22, 2011

Recommended maintenance parts & accessories

Show 3 more
No more item to show