Craftsman 3gal 1HP air compressor -- issue w/ regulator gauge & low PSI

A:

Thank you for your question on the difference in the pressure gauge readings.

I have contacted the manufacturer and they say there can but up to a 5% difference in the tank pressure reading and the outlet pressure reading and that it is normal for this model. That 5% percent in this case relates to 10 psi difference.

I hope this will reassure you that you compressor is working normal.

Sam A.

Read More
Sam A -
Sears Technician
September 28, 2012
A:

Thank Brandon for your question on the air tools and compressors issues. It is normal for the gauges to be off as much as 5% and you probably are getting the 125 psi when the unit shuts off. Change the oil the first time at about 10 hrs and then every 100hrs. Use a SAE 30 weight oil. It will take about 3 to 4 ounces or until the oil reaches the center dot in the sight gauge. All air tools leak a little and if you have to put you ear up to it to hear it then I would not be concerned and since you bought it used it has a little wear already but unless it is hissing real loud I would not be concerned. Make sure that the hissing is not coming from the quick coupling because they are notorious for leaking. Sam A.

Read More
Sam A -
Sears Technician
October 01, 2012