Q:

Kenmore Ultra Fabric Care Heavy Duty 90 Series Dryer Model #11097591400 soft heat - trouble with drying timer

A:

Thank you for your question and I understand your concern.

Based on your symptom and details I would suspect a faulty timer. Whenever the timer is turned on, timer contact switch #1 must close. If timer contact #1 (Black and Blue) does not close, it will not start. Also, timer contact switch #4 (White and Tan) must also close or the motor will not start. One of the two timer switches is not likely closing in order to complete the circuits to the motor. I added an image below of the wiring diagram.

I recommend calling a service technician in order to properly diagnose and repair your dryer.

I hope this is helpful. If I may be of further assistance as more details become available, please reply to this post.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Read More
Joey S -
Sears Technician
November 12, 2012