my dryer does not get hot. The ignitor works. It takes 3 times to get clothes dry. my model number is Kenmore 600 series 110-77642600.

A:

Based on your symptom there could be one of two likely issues or failure.

  • Restriction in the vent system
  • Weak solenoid coils
To determine if you have a restriction in the venting system temporarily disconnect the vent hose from the back of the dryer and dry one load of clothes. If the clothes dry in a normal amount of time then this test would prove there is restriction or an improperly vented dryer.

If the clothes still takes 3 cycles to dry with the vent hose disconnected then the likely failure is weak gas solenoid coils. Pry the little plastic square inspection off from below the door and then start the dryer. Watch the glow bar igniter operation. If you find the igniter glowing red and then fade back off without any burner ignition then both gas valve solenoid coils will need to be replaced. NOTE: Disconnect the power cord from the power source before servicing your dryer.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .