Q:

refrigerator (Kenmore model 10657362700) side by side (purchased 2007) will not get cold. How can I clear the cap tubes? Compressor works fine.

A:

I am sorry the refrigerator is giving you problems. The cap tube can be plugged on a refrigerator. This is caused by impurities in the sealed system however to determine a blockage someone would have to install access valves in the system. If no one has installed access valves and checked the pressures, they would not know what the problem is. Some technicians can use a wattmeter to diagnose a refrigerator but they cannot narrow it down to a plugged cap tube with a wattmeter. If the cap tube is plugged a service tech can try to clear the line with compressed nitrogen. Then a new filter drier has to be installed. The system has to be properly checked for leaks then recharged. A qualified service technician does this type of repair. I recommend having a service technician properly diagnose the refrigerator for you. The problem could be just a wire off of the compressor. I hope this is helpful.

Thank you for using Manage my life.

Here is a link to order any parts you need. Sears Parts Direct .

You can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .