Q:

Amana refridgerator model SCD23VBW-P1315305WW and evap ciol is froze up , pulled cover off inside freezer and fan on evap is not running

A:

Providing some more detail to your question will definitely help an expert better your search. If you would like to resubmit your question that would be very helpful. Have a nice day.

Read More
Alina F. -
December 05, 2010
A:

let the evap coil defrost by unpluging refridgerator and then pluged it back in and evap fan was running so i put the cover back on, closed the doors and checked on it again like 30 min. later and the evap fan was not running. the compresser and cond. fan are on

Read More
Wade -
December 05, 2010
A:

The evaporator fan motor gets 120 volts ac if the main thermostat and the defrost thermostat are closed.

Someone needs to check the voltage to the evaporator fan motor. If the fan motor is getting 120 volts and not running the fan motor is bad.

If the defrost thermostat, which is clamped to the evaporator coil, is open, the fan motor nor the defrost heater will work.

You could have a bad evaporator fan motor, a bad defrost thermostat, or a bad defrost heater.

If you are not comfortable making these voltage checks, you can go to http://services.sears.com/shs/category/repair?sid=MMLxexpertxmerch and get a Sears technician to repair the refrigerator.

Read More
Jimmy K -
Sears Technician
December 06, 2010
A:

Thanks for your help.I checked the voltage at the fan motor and it had 120 volts when checking from terminals to ground but when i checked terminal to terminal i had nothing. i looked at the scamatic and saw it gets the neutrel though the defrost timer so i turned the manual nob and sent it into defrost cycle after that the evaperator fan moter came on and has been working until today,,,,it looks like it is doing the same thing now

Read More
Wade -
December 11, 2010