Q:

current draw RAD101B Comfort Aire Room a/c

A:

Based on you symptom and details, the compressor is not starting due to low voltage, bad capacitior or possibly the compressor is locked.

If the A/C is not cooling and you notice or measure a current spike when the compressor attempts to start, the compressor could be locked up or a bad capacitor. If the compressor will start and run, it should pull approximately 9.2 Amps.

Also, if the voltage supply is low, the compressor will not start.

Read More
Joey S -
Sears Technician
August 17, 2015
Q:

when disconnecting engne coolant temperature sensor both fans come on.Is this result of bad ECT senor

A:

When my vehicle starts acting up I just see money going out the window, either in repair cost, or replacement. Managemylife.com can take the mystery out of the repair. Your expert can help you determine if you should consider replacing or repairing an older vehicle. I did some research for you and found this link to a similar question which may shed some light on the problem. I hope this helps until your expert answers.

Read More
James -
September 29, 2012
A:

ECT is seeing an open in that circuit and turning the fans on so as not to overheat and cause any damage. Check the ohm reading of the sensor as it heats up to make sure it is changing.

Read More
MikeLangton -
Sears Technician
October 01, 2012
See more answers
Q:

when disconnecting engne coolant temperature sensor

A:

When my vehicle starts acting up I just see money going out the window, either in repair cost, or replacement. Managemylife.com can take the mystery out of the repair. Your expert can help you determine if you should consider replacing or repairing an older vehicle. I did some research for you and found this link to a similar question which may shed some light on the problem. I hope this helps until your expert answers.

Read More
James -
September 29, 2012
A:

The ECM is going into default mode turning the fan on because it is seeing an erroneous reading.

Read More
MikeLangton -
Sears Technician
October 01, 2012
See more answers