Q:

Why won't the condenser fan motor run?

A:

You will need to check for 12vdc from pink to white. When making this check, all wires must be connected. Do not disconnect any wires or connectors. First make this check at the main board, at the J2 connector. If there is no voltage from pink to white, the board # WR55X10942 will have to be replaced. If there is voltage at the board on these 2 wires, you will need to check voltage at the motor, from pink to white and again, do not disconnect any of the wires. If there is 12vdc at the motor, it will need to be replaced again but if there is no voltage there, it will indicate a broken wire, between the board and the motor. If you need more assistance, you can resubmit your question with more details.

Read More
Scott D -
Sears Technician
September 29, 2009
A:

GE Profile Refrigerator Arctica Model PSS26NPGA: Condenser Fan motor has 4 wires:White,Red,Blue, and Yellow. The Fridge itself has 3 wires coming from the mainboard with colors Pink, Yellow, and White. Where should the fan motor wires go? I tested White (Fridge side) - Pink (Fridge side) gave 12-13 VDC Also White (Fridge side) - Yello (Fridge side) gave me 12-13 VDC Should I connect the following: White(Fan motor) - White (Fridge) Yellow (Fan motor)- Pink (Fridge) Red (Fan motor) - Yellow (Fridge)

Read More
Anonymous -
March 28, 2013
A:

I have 12VDC between white and pink and also 12VDC between yellow and white (wires coming from Main board) ......but my question is : DoI connect the following: White(Fan motor) - White (Fridge) Yellow (Fan motor)- Pink (Fridge) Red (Fan motor) - Yellow (Fridge)

Read More
Anonymous -
March 29, 2013