1993 gas Tempstar direct vent 90%


I know this type of information can be very helpful for you to have. While you are waiting for your expert answer, I did some research on the unit. I was unable to locate information that would be helpful with regards to your question at this time. Your expert will answer within 24-48 hours with detailed information. Thank you for using Manage My Life.

Read More
aashe -
December 30, 2011

Thank you for your question. I know it's frustrating when the furnace stops working. Based on the information listed, it sounds like the transformer # 90-T40M3 has failed. A good check will be to check the voltage coming into the transformer on the white and black wires on one side for 120 volts and then the yellow and black wires on the other side for 24 volts. If it has 120 volts coming in but no low voltage coming out, the transformer will need to be replaced. Be very careful when making this voltage check. Also check for any wires that could be shorted because it's a very common reason for the transformer to fail. I hope this will help you.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Safety Notice: Be sure to disconnect the appliance before performing any troubleshooting procedures. If you are not comfortable with doing any voltage checks or repairs that might be recommended, please contact a local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.

Read More
Scott D -
Sears Technician
January 03, 2012
See more answers