Q:

I have the following Dryer: GSGQ642AS4. Dryer will not heat. I replaced the burner and the ignitor. Manual say's check fuses. Where are they located? GLGQ642AS4 Frigidaire Dryer

A:

Thank you for choosing Sears Parts Direct. I will be more than happy to help with your dryer. Upon researching GSGQ642AS4; there is a safety thermostat on the back panel. There is a radiant sensor on the side of the burner tube. I linked the diagrams below. The radiant sensor is number 79 on the burner diagram. The safety thermostat is number 33 on the cabinet/drum diagram.

If you have any further questions please re-post. We appreciate your business. Have a great day.

Read More
Jeff Wallace Jr -
Sears Technician
October 03, 2014
A:

Thank you. I replaced the control module as recommended by a rep over the phone. The dryer still does not heat. The igniter is getting red/hot. I have power thru the safety t-stat, power to the radiant sensor on the side of the burner and power to the coils on the gas valve. Any thoughts?? I am thinking the coils are gone?? I have also replaced the burner and igniter already . Appreciate some insight. Thx

Read More
Tucker -
October 05, 2014
A:

Thank you. I replaced the control module as recommended by a rep over the phone. The dryer still does not heat. The igniter is getting red/hot. I have power thru the safety t-stat, power to the radiant sensor on the side of the burner and power to the coils on the gas valve. Any thoughts?? I am thinking the coils are gone?? I have also replaced the burner and igniter already . Appreciate some insight. Thx

Read More
Tucker -
October 08, 2014
A:

Thank you. I replaced the control module as recommended by a rep over the phone. The dryer still does not heat. The igniter is getting red/hot. I have power thru the safety t-stat, power to the radiant sensor on the side of the burner and power to the coils on the gas valve. Any thoughts?? I am thinking the coils are gone?? I have also replaced the burner and igniter already . Appreciate some insight. Thx

Read More
Tucker -
October 08, 2014
A:

Thank you. I replaced the control module as recommended by a rep over the phone. The dryer still does not heat. The igniter is getting red/hot. I have power thru the safety t-stat, power to the radiant sensor on the side of the burner and power to the coils on the gas valve. Any thoughts?? I am thinking the coils are gone?? I have also replaced the burner and igniter already . Appreciate some insight. Thx

Read More