Q:

Lightning Strike and Not Cooling FRS26R2AQ3 Frigidaire Refrigerator

A:

Thank you for choosing Sears Parts Direct. I will be more than happy to help you with that.
Upon researching model FRS26R2AQ3 I found a couple things that can go out due to lightning or power surges. FIrst if the compressor is not going on at all then there's the capacitor and the starter kit that is located on the compressor. I would start with those being they cost less. Then there is the temperature control. If that is out it won't tell the compressor to turn on.

Click here for diagram. Number 30 is starter kit. Number 55 is capacitor.

Click here for temperature control. Number 21a is the temperature control it is the one on the left side.

If you have any further questions please repost. Thank you for choosing Sears. Have a great day.

Read More
Samantha A -
Sears Technician
May 14, 2014
Q:

How do I wire the PTC for my Frigidaire refrigerator?

A:



The red wire goes on the overload. The blue wire goes on the run capacitor with the wire that attaches to the # 2 terminal on the PTC.

Read More
expert -
Sears Technician
March 11, 2008