Stove ignition FGGF3054KFC Frigidaire Gas range


Thanks for the inquiry and for being a valued member.

This could indicate a bad ground connection between the base and top.

In order for the non-working spark electrode to work, the spark igniter module must supply voltage to the electrode and the burner base must be making a good ground in order for the voltage to jump across the electrode to the base which should be grounded. It is possible to have a failed spark igniter module but not likely. I would check the wiring connection. If the wiring checks out and looks good, you will need a meter to verify if the burner electrode is receiving power from the module. If so, the burner itself will need replacement. If not, the module will need to be replaced.

If you would feel more confident have a Sears Home Service technician help assist with the diagnosis/repair, you can call 1-800-469-4663, or click here to be directed to the page to set up service.

I hope this helps and thanks for using We appreciate your business.  