Model #EE3J50RD045V AMERICAN WATERHEATERS Water heater, Electric

  • Water Heater
    3 Results
Find part by diagram >

Question and Answers

Q:

Am i supposed to cut the anode rod to the correct length? EE3J50RD045V

A:

Thank you for being Sears’ valued member and for contacting SearsPartsDirect.com with your question about the anode rod for your water heater model EE3J50RD045V. I am sorry the part needs to be replaced. I will be happy to help you with this.

You can cut the anode rod to the length you need. The best way to cut the anode rod is with a hacksaw. Use a file to smooth the cut and install the rod.

I hope this answers your question. Thank you for choosing Sears, we appreciate your business.

 

Read More
Rachel Morgan -
Sears Technician
October 11, 2014
Q:

Sometimes no hot water. EE3J50RD045V American Waterheaters Water heater

A:

I am having the same problem but I replaced both elements and the water is not heating consistently. After a couple of days it shows a high temparture on the control pannel then we have no hot water a day later. Would the thermostat or electrical panel be causing the problem?

Read More
Todd -
March 18, 2014
A:

Thanks for your question- we see that no one from the community responded.  If you still require assistance on this topic, please resubmit your question with any updated information and we will have one of our experts take a look.  Also, we have updated our site to include information regarding common repairs and diagnosis, which can be found here: www.searspartsdirect.com/repair-help.html.  If you are looking for your owner’s manual, it can be found here: http://www.searspartsdirect.com/partsdirect/user-manuals.  Thanks for visiting SearsPartsDirect.com.

Read More
Natasha12 -
Sears Technician
May 09, 2014
See more answers
Q:

Heating element wont stay on. hot water tank

A:

I know how important it is to have a good working hot water heater in the home. I am sorry for the inconvenience and I did manage to find a link with a similar question. The expert will respond within 24 to 48 hours, thank you for your patience.

Read More
Joseph P. -
June 25, 2012
A:

Thank you for your question. I know it can be frustrating when the water heater stops working. The resistance for the elements is good but also check each element to ground. If you get a reading to ground, the element will need to be replaced. If there is no reading the elements are ok. This would lead to a defective thermistor # 6910545 or control # # 6910605 board. I'm attaching some pictures and information to check the thermistor. Be sure to disconnect the power first. If it checks ok, the control board will need to be replaced. I hope this will help you. If you would like more assistance, reply to this thread and I will be glad to assist you further.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Read More
Scott D -
Sears Technician
June 28, 2012
See more answers