Q:

I have a Danby DWC512BL wine cooler that runs constantly when plugged in and the temperature drops well below the target. DWC512BL

A:

Thank you for choosing SearsPartsDirect.com. I will be more than happy to assist you. I can understand any frustration you may have experienced with regards to your unit. Let’s see what we can do for you.

The information I have pulled on this Danby wine cooler is the sensor or controller as malfunctioned. I would suggest replacing the temp sensor. The correct part would be DG8-3. If it’s not the sensor then the controller would need to be replaced. That part number is JG50.DQ-02. 

Hope this information has helped you. If you are not comfortable doing this repair you can click here to schedule a technician or call toll free 1-800-469-4663. Again, thank you for choosing SearsPartsDirect.com.

 

Read More
JeffwallaceIII -
Sears Technician
December 08, 2014
A:

Replacing the temp sensor fixed the problem. It was easy to replace. Thanks!

Read More
Jason -
January 05, 2015
See more answers