Q:

I have a dryer model number DNSR475GY0WW and it won't stay running when I release the start knob

A:

Managemylife.com is always a great resource to find the answers to just about anything. Your expert will research your question and respond within two business days but usually sooner. Have a great day!

Read More
Alina -
January 12, 2013
A:

Thank you for your question and I understand your concern.

If you have constant voltage at M6 when timer is turned on, I suspect the motor centrifugal switch contact M5 and M6 is not closing once the motor starts. If contacts M5 and M6 is not closing, the motor will not remain running when start is released. The motor kit #WE17X10010 can be ordered from Sears Parts Direct.

This may be the issue. If not, please reply and I will be glad to assist you further.

Read More
Joey S -
Sears Technician
January 14, 2013
A:

I added a larger image of the wiring diagram below. If contacts M5 and M6 is not closing when the motor starts, the motor is not going to remain running once the start button is released.

Read More
Joey S -
Sears Technician
January 14, 2013
A:

Thanks Joey S for your help....

Read More
Anonymous -
January 15, 2013
See more answers