I am sorry that you are having some difficulties with your dryer and I will be happy to help. I did some research and I was able to find a link that will provide you with some good information. I hope this helps with your dryer troubles while you wait for your expert response.

Read More
Joseph P. -
September 05, 2012

The most likely cause of that failure is the gas valve coils. Since the burner ignites properly from a cold start, the flame sensor and other components in that heating system are apparently okay. Weak gas valve coils may be strong enough to open the gas valves from a cold start but they will not be able to open the gas valves on subsequent ignition attempts. The theory of operation for that gas burner assembly is shown in the first image below. If the igniter is glowing and then fading off when the dryer is running in a heated cycle then that flame sensor is okay. In that situation, replacing the gas valve coils (part WE04X10020). That kit WE04X10020 has both coils. You can order it from this page: Coil Kit for General Electric Dryer Model DBL333GB5WW . Unplug the dryer and shut off the gas supply before accessing and replacing internal components.

The second image below shows some access information for that dryer. You should be able to use that information to access and replace those gas valve coils.

If you need more help, reply with additional details.

If you get to the point where you need to have a service technician diagnose and repair this failure, you can schedule service through this link: Sears Home Services .

Read More
Lyle W -
Sears Technician
September 07, 2012
See more answers