Q:

Dryer won't start AGQ6000ES1

A:

Thank you for choosing SearsPartsDirect.com and being a valued member.  I can certainly understand how frustrating it can be when your dryer is not working properly. 

If the door switch is okay, then you could have a failed control board, a defective thermistor, a bad drive motor or a wiring failure in the motor circuit. 

I have attached the diagnostic instructions. 

Does the control beep or the LED flash when the start button is pushed.? 

If yes, Is an error code displayed? No- Measure the voltage drop between pins 1 & 2 of J-4. If you get 120 it is a defective control board. If it is 0 then it is the door switch. 

If no, Measure the voltage drop between the red wire on the thermal limiter and neutral. 

120vac= Measure the voltage drop between the orange wire on the thermal limiter and neutral. If 0, Defective thermal limiter. If 120, Measure the voltage drop
between pins 1 & 2 of the eight pin plug of the wire
harness to the control board.
120 defective control board.

You can also visit searpartsdirect.com for parts, diagrams, and repair information.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Thank you for your question. Have a great day.

SAFETY NOTICE: Be sure to disconnect power to the appliance before performing any repairs. If you are not comfortable with doing any voltage checks that might be recommended, please contact your local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.

 

 

Read More
Natasha12 -
Sears Technician
July 05, 2015
Q:

Dryer won't start AGQ6000ES1 Frigidaire Dryer

A:

Thank you for choosing SearsPartsDirect.com and being a valued member.  I can certainly understand how frustrating it can be when your dryer is not working properly.

If the door switch is okay, then you could have a failed control board, a defective thermistor, a bad drive motor or a wiring failure in the motor circuit. 

I have attached the diagnostic instructions. 

Does the control beep or the LED flash when the start button is pushed.? 

If yes, Is an error code displayed? No- Measure the voltage drop between pins 1 & 2 of J-4. If you get 120 it is a defective control board. If it is 0 then it is the door switch. 

If no, Measure the voltage drop between the red wire on the thermal limiter and neutral. 

120vac= Measure the voltage drop between the orange wire on the thermal limiter and neutral. If 0, Defective thermal limiter. If 120, Measure the voltage drop
between pins 1 & 2 of the eight pin plug of the wire
harness to the control board.
120 defective control board.

You can also visit searpartsdirect.com for parts, diagrams, and repair information.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Thank you for your question. Have a great day.

SAFETY NOTICE: Be sure to disconnect power to the appliance before performing any repairs. If you are not comfortable with doing any voltage checks that might be recommended, please contact your local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.