Question and Answers

Q:

Why does this motor(5kcr49tn2235x)keep tripping breakers?

A:

The part number you provided does not appear to be a correct or valid part number. Without having the model number of the product I will not be able to provide any model specific information.

Resubmit your question with the model number of the product with additional details for model specific information.

Read More
Joey S -
Sears Technician
April 19, 2010
A:

I also am having this problem. It is the motor on a Craftsman air compressor 919.165220. 5HP 22Gal. The motor is a GE #5KCR49TN2235X. The capacitors on mine seem to be fine and the motor starts to spin but then trips the breaker?? I'm at a loss...

Read More
Bert -
July 15, 2010
A:

I have a sears compressormodel 919.165220 5hp that when the motor turns on it runs for a short time and trips the breaker ?

Read More
steve -
July 16, 2013
A:

Hi Steve, sorry we have not got to you sooner. This conversation is over 3 years old so it didn't show up in our list of questions that needed to be answered.

Based on the information you have provided it sounds like you have a blown fuse. First check the fuse box for a blown fuse and replace. Reset Circuit breaker, do not use a fuse with a higher rater than what is specified for your particular unit.  Second, make sure the fuse is a time delay fuse. Third, also check for low voltage conditions or a proper extension cord if one is being used.

I hope this helps in fixing your air compressor.

If you have further questions please let me know.
Thanks for using ManageMyLife.com

 

Read More
Desirea -
Sears Technician
August 23, 2013
A:

I have exactly the same compressor and motor. I don't have a blown fuse. the compressor starts and runs about 6 seconds then trips the breaker. I can repeat the problem at my house and my neighbor's house. Any Help is appreciated.

Read More
Lee -
July 07, 2015
A:

It would seem I need to wait 3 years before my question is answered, so let me tell you what I found. I had the identical problem. It's an oilless air compressor Craftsman model 919.165200 Turned out to be the Run Capacitor. Replaced with GE Genteq Capacitor Round 40 uf 370 Volt VAC Z97F9614 97F9614 (found on eBay for $15.85 The unit runs well now and doesn't blow the breaker. (same problem for this guy: http://www.homeownershub.com/maintenance/sears-air-compressor-throws-breaker-189975-.htm ) -Lee

Read More
Lee -
July 11, 2015
A:

Well I don't have two years. I have the same model with the same problem. Is it a hard repair? Thanks, Tracy

Read More
Tracy -
August 18, 2015
See more answers
Q:

Wiring diagram for 220 919165220 Craftsman Air compressor

A:

Thank you for your inquiry on your Craftsman Air Compressor, Model: 919.165220. From reviewing the details on your model, unfortunately the wiring diagram for this air compressor is no longer available in our system. The only  other thing I could recommend would be contacting craftsman but since you already went that route there would be no other place to obtain the wiring diagram.  

I hope this answered your question. Thank you for contacting SearsPartsDirect.com, and have yourself a wonderful day. 

Read More
Gerry 93 -
Sears Technician
April 24, 2015
Q:

how to get the to screws out of the front cover 919165220 Craftsman Air compressor

A:

Thanks for the inquiry and for being a valued member.

Based upon the visual of the screws on Sears Parts, it looks like they are going to be a Torx head. More than likely a T25. 

I hope this helps and thanks for using SearsPartsDirect.com. We appreciate your business. 

Read More
Jeff Wallace Sr -
Sears Technician
March 08, 2015

Top Parts