Q:

tube blowing off compressor check valve?

A:

When it comes to troubleshooting your Compressor owners manuals are the best to have. While you are waiting on an expert to answer your question, I found your owners manual in the Manage My Life website. I have attached the link below. Have a nice day!

Read More
Dezeray -
June 26, 2012
A:

Thank you for your question on the air compressor air line blowing off the check valve.

These should have compression fittings that hold both the outlet tube and the relief tube to the check valve.

All you may have to do is pick up some new compression fitting locally and if you can re-cut the tubing with out it being to short, and you may be able to repair it with out having to order parts.

Some of the original compression sleeves where rubber but you can replace them with brass compression fittings.

Unless the check valve is cracked I do not think you will need to replace it.

Please let me know what you find out about the fittings and we can continue to troubleshoot with that information if needed.

Sam A.

Read More
Sam A -
Sears Technician
June 29, 2012
A:

I have the same issue. I've tried replacing the plastic tube but can't find one that will withstand the heat of the check-valve connection which is simply a slip connector. The other end is a compression fitting which holds well. This part is not shown as an available part. Is there a way to convert the check valve end to a compression fitting (which appears to be perhaps an 1/8") and go with copper which is malleable and impervious to the heat build up? This unit has been a paper weight for a 2 years thus far until I can come up with a remedy. Thank you in advance for you assistance. Don Adam, Columbus, OH

Read More
DONALD -
October 22, 2015
See more answers
Q:

Why does this motor(5kcr49tn2235x)keep tripping breakers?

A:

The part number you provided does not appear to be a correct or valid part number. Without having the model number of the product I will not be able to provide any model specific information.

Resubmit your question with the model number of the product with additional details for model specific information.

Read More
Joey S -
Sears Technician
April 19, 2010
A:

I also am having this problem. It is the motor on a Craftsman air compressor 919.165220. 5HP 22Gal. The motor is a GE #5KCR49TN2235X. The capacitors on mine seem to be fine and the motor starts to spin but then trips the breaker?? I'm at a loss...

Read More
Bert -
July 15, 2010
A:

I have a sears compressormodel 919.165220 5hp that when the motor turns on it runs for a short time and trips the breaker ?

Read More
steve -
July 16, 2013
A:

Hi Steve, sorry we have not got to you sooner. This conversation is over 3 years old so it didn't show up in our list of questions that needed to be answered.

Based on the information you have provided it sounds like you have a blown fuse. First check the fuse box for a blown fuse and replace. Reset Circuit breaker, do not use a fuse with a higher rater than what is specified for your particular unit.  Second, make sure the fuse is a time delay fuse. Third, also check for low voltage conditions or a proper extension cord if one is being used.

I hope this helps in fixing your air compressor.

If you have further questions please let me know.
Thanks for using ManageMyLife.com

 

Read More
Desirea -
Sears Technician
August 23, 2013
A:

I have exactly the same compressor and motor. I don't have a blown fuse. the compressor starts and runs about 6 seconds then trips the breaker. I can repeat the problem at my house and my neighbor's house. Any Help is appreciated.

Read More
Lee -
July 07, 2015
A:

It would seem I need to wait 3 years before my question is answered, so let me tell you what I found. I had the identical problem. It's an oilless air compressor Craftsman model 919.165200 Turned out to be the Run Capacitor. Replaced with GE Genteq Capacitor Round 40 uf 370 Volt VAC Z97F9614 97F9614 (found on eBay for $15.85 The unit runs well now and doesn't blow the breaker. (same problem for this guy: http://www.homeownershub.com/maintenance/sears-air-compressor-throws-breaker-189975-.htm ) -Lee

Read More
Lee -
July 11, 2015
A:

Well I don't have two years. I have the same model with the same problem. Is it a hard repair? Thanks, Tracy

Read More
Tracy -
August 18, 2015
See more answers
Q:

Craftsmans aircompressor wiring 919.165200

A:

Thank you for choosing Sears Parts Direct. I will be happy to help with your air compressor. Upon researching model 919.165200; not all units are convertible. If the unit is convertible there would be a wiring diagram under the motor cover or the pressure switch.

Thank you for choosing Sears. We appreciate your business. Have a great day.    

Read More
Jeff Wallace Jr -
Sears Technician
December 29, 2014