Q:

Craftsman air compressor tripping relay on restart.

A:

Air compressor are a very great appliance to have.When it begins to malfunction it can be a huge inconvenience. I have done some research on the Manage My Life website and have located several link towards your issue. While you are waiting for a detailed reply from an expert I have provided the links below. Hope this helps!

Read More
Priscilla V -
April 19, 2012
A:

I messed up on model #. It is 919.153530

Read More
jason -
April 19, 2012
A:

Thank you for your question. I am sorry you are having a problem with the air compressor. I suspect the problem with the compressor is a defective start capacitor. To be sure this is the problem, move the compressor to a different outlet. Plug the compressor directly into the outlet and check the operation. If the compressor does the same thing and providing you do not hear any leaks, I recommend replacing the start capacitor. The capacitor is located on the motor. To access it you will need to remove the motor cover. Then you will see two humps on the motor. This is where the capacitors are located. Remove the covers to expose the capacitor. Remove the capacitor and purchase a replacement from a local electrical supply house. You have to find the capacitor locally because the manufacturer does not offer the capacitor separately. I hope this is helpful. Please let me know if you need further assistance. Thank you for using Manage my life. Mark T.

Read More
Mark T -
Sears Technician
April 22, 2012