Question and Answers

Q:

how do I access the erc panel on my stove 9113674990

A:

Thank you for choosing Searspartsdirect.com and being a valued member. I can certainly assist you. 

Removing Manifold Panel
Remove the four mounting screws on the
underside of the manifold panel. Remove the
burner valve control knobs by pulling them
straight forward off the valve shafts.

Next remove the three ¼” hex head screws
securing the top of the manifold panel and
remove the panel.

With the manifold panel removed the surface
burner ignitor switches and harness are
accessible. The wire harness and switches are
replaced as a complete assembly.

To remove the switches and harness from the
burner valves loosen the wire twist ties that
secure the wire harness to the manifold pipe. Pull
forward to unsnap the switch housing from the
valve. When replacing the switches make sure
that the switches snap securely and lock to the
valve body. The slack in the wire harness should
lay under the manifold tube and secure with the
wire twist ties.

You can also visit searpartsdirect.com for parts, diagrams, and repair information.

If you do not feel confident repairing this problem yourself, then you can have it repaired at your home by a Sears technician. Here is a link for the website: Sears Home Services .

Thank you for your question. Have a great day.

SAFETY NOTICE: Be sure to disconnect power to the unit before performing any repairs. If you are not comfortable with doing any voltage checks that might be recommended, please contact your local service provider for repairs. Be aware that there could be sharp edges inside the appliance that could cause cuts or other injuries to yourself or others.

Read More
Natasha12 -
Sears Technician
August 03, 2015
A:
Natasha12 -
Sears Technician
August 03, 2015
See more answers
Q:

Why is the oven not working correctly on my Kenmore range?

A:

It sounds like the igniter is weak. If the igniter is weak the burner will take a long time to come on. The electrical current draw of the igniter is what triggers the gas valve to open. You will need an amp meter to test the current draw of the igniter. The correct current amp draw will be between 2.5-2.8.

Read More
biker dave -
Sears Technician
May 06, 2009