Question and Answers

Q:

furnace pilot 867761823 Kenmore Sears gas-fired sectional furnaces

A:

Hello glad to help.  Thank You for choosing Sears PartsDirect.com

I am sorry and do understand your frustration when having trouble with the furnace.

Glad to help out.   Im  looking at your model number  867.761823.

It sounds like your thermo couple is going bad.  When coming on you said the flame is red so that usually means your ignitor is good at least.  I would replace the thermo couple tubes from the pilot to the ignitor.

Thermo couple per model 867.761823 

If you have further questions please let me know.

Thanks for choosing Sears PartsDirect.com 

Read More
Larry L -
Sears Technician
September 20, 2013
A:

I just put a new thermo coupler in. is there any way to adjust the pilot so the flame is bigger?

Read More
john -
September 20, 2013
A:

Hello glad to help.  Thank You for choosing Sears PartsDirect.com

John thanks for writting back.  I see no other way to adjust the pilot to make the flame bigger.   I would get a professional to look at it but what you are saying and from experience, I am certain you just need that thermo couple tube.   

If you have further questions please let me know.

Thanks for choosing Sears PartsDirect.com

 

Read More
Larry L -
Sears Technician
September 23, 2013
See more answers
Q:

The fan doesn't turn off in our gas furnance #867761823. I want to order control switch #5d51-90 for the fan & limit switch. It appears differant, I am

A:

I know this type of information can be very helpful for you to have. While you are waiting for your expert answer, I did some research on the unit. I was unable to locate information that would be helpful with regards to your question at this time. Your expert will answer within 24-48 hours with detailed information. Thank you for using Manage My Life.

Read More
aashe -
December 14, 2011
A:

The original fan and limit switch probably has one wire that connects to 2 terminals. The replacement fan and limit switch probably has an internal jumper so it uses 3 terminals.

I don't have a wiring instruction sheet to reference this problem. If you can send images of both fan and limit switches showing the wiring terminals I can probably tell you how to wire the switch.

Read More
Jimmy K -
Sears Technician
December 17, 2011
A:

Jimmy K, I have the image on my cell phone. How can I get it to you. Can I send it to you from My phone. Dave B

Read More
David -
December 20, 2011
A:

David, I sent you an email address to send the images to. I hope you got the email.

Read More
Jimmy K -
Sears Technician
December 22, 2011
See more answers