Q:

exercise bike model

A:

Exercise may be just as effective if not tracked but it is hard to maintain focus on the goal if the display is not working. While you wait for the expert review, you can check a similar question for a slightly different model of Weslo. I attached below. I also added the owner's manual for your model below for additional information. Hope this information helps you get back to your exercise routine.

Read More
Barbara H. -
June 11, 2011
A:

You could have a defective reed switch, broken wire from the reed switch to the console, or a defective console.

The answer Barbara H sent has a good description of testing the reed switch. I would start by disconnecting the reed switch from the console. Connect an ohm meter across the pins in the reed switch connector and rotate the pedals slowly. If the reed switch is showing 0-2 ohms when the magnet in the flywheel passes it, the console is bad.

To remove the left side panel, you have to remove the left pedal. Turn the pedal clockwise to unscrew it from the crank arm.

The part number and price of the reed switch and the console are:

06 831 185207 1 $9.99 831283100 REED SWITCH/WIRE 06 831 185850 1 $66.99 831283100 CONSOLE

You can order the console or reed switch at Parts Direct If you are not comfortable diagnosing and repairing the exercise bike, you can go to Home Services and get a Sears technician to repair the bike.

Read More
Jimmy K -
Sears Technician
June 13, 2011
See more answers
Q:

exercise bike mod# 831283100 changed battery panel shows only zeros the numbers never change

A:

Exercise may be just as effective if not tracked but it is hard to maintain focus on the goal if the display is not working. While you wait for the expert review, you can check a similar question for a slightly different model of Weslo. I attached below. I also added the owner's manual for your model below for additional information. Hope this information helps you get back to your exercise routine.

Read More
Barbara H. -
June 11, 2011
A:

You could have a defective reed switch, broken wire from the reed switch to the console, or a defective console.

The answer Barbara H sent has a good description of testing the reed switch. I would start by disconnecting the reed switch from the console. Connect an ohm meter across the pins in the reed switch connector and rotate the pedals slowly. If the reed switch is showing 0-2 ohms when the magnet in the flywheel passes it, the console is bad.

To remove the left side panel, you have to remove the left pedal. Turn the pedal clockwise to unscrew it from the crank arm.

The part number and price of the reed switch and the console are:

06 831 185207 1 $9.99 831283100 REED SWITCH/WIRE 06 831 185850 1 $66.99 831283100 CONSOLE

You can order the console or reed switch at Parts Direct If you are not comfortable diagnosing and repairing the exercise bike, you can go to Home Services and get a Sears technician to repair the bike.