Q:

HAVE AN ELECTRIC RANGE THAT "ELEMENTS ON" LIGHT WILL NOT GO OUT. BURNERS HAVE DIALS OFF AND NO HEAT IS ON BURNER. ANY DANGER IN USING AS IS, OR NEED PARTS?

A:

When your Range has an issue it can be really frustrating. While you are waiting on an expert to answer your question, I suggest you set service with a Sears technician so they can fix this for you. Click here. Hope this helps!

Read More
Dezeray S -
July 13, 2013
A:

I am having the nsame problem is that their answer? Set up a service call???

Read More
Sandy -
July 14, 2013
A:

I know that it can be very frustrating to have issues with your range. The element "ON" indicator is turned on and off by each one of the surface element burner switches. One of the switches is likely faulty. There is a terminal on each one of the burner switches marked or labeled with a letter "P". When any one of the switches are turned on, terminal "P" will have 120 volts supplied to "ON" indicator and it turns on. One way to determine which switch is faulty is to disconnect the power cord from the power source and then access the burner switches. Disconnect just the one wire connected to terminal "P" and make sure the disconnected wire is not touching any metal ground or any other terminals. Plug the power cord in and see if the "ON" indicator is on or off. If it's off, the switch you pulled the wire off from is the faulty switch. If the light stays on, disconnect the power cord and reconnect the wire. Go to the next switch and remove the wire from terminal "P" and repeat the process until you find that the "ON" indicator stays off and then replace that burner switch. You may be able to determine which burner switch is causing this problem on your own through a process of elimination. Unplug the range and access the burner switches as shown in this brief repair video: Electric Range Infinite Burner Switch Replacement . Once you find the switch that causes the Element On light to go out when that purple wire is disconnected, you can order a replacement switch from the Sears PartsDirect website. Be sure that you unplug the range before accessing internal components and replacing that switch. The video provided above shows the burner switch replacement procedure. I hope this helps. If you need further assistance, please reply to this thread. Thank you for using Manage My Life.

Read More
AnneJ -
Sears Technician
July 14, 2013
See more answers
Q:

Glass top stove is scorching from underneath. What is causing this and is this still safe to use? mod # 79096002602 (front 2 burners only)

A:

know this type of information can be very helpful for you to have. While you are waiting for your expert answer, I did some research on the unit. I was unable to locate information that would be helpful with regards to your question at this time. Your expert will answer within 24-48 hours with detailed information. Thank you for using Manage My Life.

Read More
Priscilla V -
November 17, 2011
A:

I can understand why you would want to make sure it's safe. The range is fine to use as long as the glass is not broken. The scorch marks are from the constant use of the burners, and the heat cycling while their on. If you don't feel confident about using it like this you can replace the burners. I have include the instructions below. If you need any further assistance, please reply to this thread.

Read More
AnneJ -
Sears Technician
November 18, 2011
See more answers